2010
DOI: 10.1016/j.jsbmb.2010.03.033
|View full text |Cite
|
Sign up to set email alerts
|

Proficiency testing of 25-Hydroxyvitamin D (25-OHD) assays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
70
1
2

Year Published

2013
2013
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 95 publications
(75 citation statements)
references
References 10 publications
2
70
1
2
Order By: Relevance
“…These values were recognized by the Endocrine Society guideline, although they differ from the ones accepted (20 ng/mL) by the Institute of Medicine (IOM) (50) (B). In general population, there is no evidence of benefit in the measurement of 25(OH)D due to the high cost, but according to the Endocrine Society, to maximize bone health; supple mentation is recommended for children up to 1 year with at least 400 IU/day; between 1 and 70 years, at least 600 IU/day while over 70 years old, 800 IU/ day (41 (52,53) and for this reason, quality control tools, such as DE QAS (International Vitamin D External Quality Assess ment Scheme) were created, as an attempt to decrease the variation in data analysis (55).…”
Section: What Are the Effects On Bone Metabolism?mentioning
confidence: 99%
“…These values were recognized by the Endocrine Society guideline, although they differ from the ones accepted (20 ng/mL) by the Institute of Medicine (IOM) (50) (B). In general population, there is no evidence of benefit in the measurement of 25(OH)D due to the high cost, but according to the Endocrine Society, to maximize bone health; supple mentation is recommended for children up to 1 year with at least 400 IU/day; between 1 and 70 years, at least 600 IU/day while over 70 years old, 800 IU/ day (41 (52,53) and for this reason, quality control tools, such as DE QAS (International Vitamin D External Quality Assess ment Scheme) were created, as an attempt to decrease the variation in data analysis (55).…”
Section: What Are the Effects On Bone Metabolism?mentioning
confidence: 99%
“…В DEQAS значения, полученные конкретны-ми лабораториями для рассылаемых ежеквартально образцов сыворотки, сравниваются как со средними значениями для конкретного метода определения витамина D (MM = Method Mean), средними значе-ниями всех методов, используемых лабораториями, участвующими в программе DEQAS (ALTM = AllLaboratory Trimmed Mean), а также универсальным стандартом (NIST = National Institute of Standards and Technology). Программа присуждает сертифи-кат качества, если целевая производительность ла-боратории соответствовала нахождению 80% всех результатов в диапазоне ± 30% от ALTM, что в 2013 г. было достигнуто только 59% лабораторий [79,80]. Таким образом, одним из путей может быть полу-чение статистического фактора коррекции между методами [81].…”
Section: клинические рекомендацииunclassified
“…Serum samples were prepared using Phree TM phospholipid removal cartridges (Phenomenex) after addition of the internal standard deuterated 25- (17) , and the use of commercially available control materials of known vitamin D concentration. Vitamin D binding protein (VDBP) was analysed using an ELISA from R&D systems.…”
Section: Sample Analysismentioning
confidence: 99%