Profile and Predictors of Normal Ganglion Cell–Inner Plexiform Layer Thickness Measured with Frequency-Domain Optical Coherence Tomography

Abstract: The independent factors associated with thinner GCIPL include thinner RNFL, older age, longer ocular axial length, and being male. Although the magnitude of the effect of age, axial length, and sex are small, these factors should be taken into account when interpreting Cirrus HD-OCT-based GCIPL thickness measurements.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

28
274
10

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 255 publications
(312 citation statements)
references
References 48 publications
28
274
10
Order By: Relevance
“…The GCA algorithm compares the values with an internal normative database, and generates thickness and color-coded deviation maps, and a significance map to match GCIPL thickness, with values within the normal range in green (P = 5% -95%), borderline values in yellow (1% < P < 5%), and values outside the normal range in red (P < 1%). Details of the manner in which GCIPL thickness measurements are conducted have been given elsewhere [12], [13]. Using SD-OCT, the RNFL thickness was measured in the optic disc cube 200 × 200 scan mode.…”
Section: A Optical Coherence Tomographymentioning
confidence: 99%
“…The GCA algorithm compares the values with an internal normative database, and generates thickness and color-coded deviation maps, and a significance map to match GCIPL thickness, with values within the normal range in green (P = 5% -95%), borderline values in yellow (1% < P < 5%), and values outside the normal range in red (P < 1%). Details of the manner in which GCIPL thickness measurements are conducted have been given elsewhere [12], [13]. Using SD-OCT, the RNFL thickness was measured in the optic disc cube 200 × 200 scan mode.…”
Section: A Optical Coherence Tomographymentioning
confidence: 99%
“…The mean GCIPL thickness measured by Cirrus SD-OCT and reported in adults has been similar even among different ethnicities: 82.1 AE 6.2 lm (Mwanza et al 2011) and 82.78 AE 7.0 lm (Koh et al 2012). On the contrary, the children in our series had a thicker mean GCIPL thickness (84.76 lm AE 5.46 lm).…”
Section: Referencesmentioning
confidence: 79%
“…To compile the database, each child underwent five axial length measurements (IOL Master, Carl Zeiss Meditec), a cycloplegic refraction and two macular scans using the ganglion cell analysis: macular cube 512 9 518 protocol with the Cirrus SD-OCT. With this protocol, the average, minimum and sectoral thicknesses of the GCIPL are measured in an elliptical annulus around the fovea. Detailed description of sectors dimensions and magnification correction is described elsewhere (Mwanza et al 2011). Images with signal strength <7 and those with visible eye motion or blinking artefacts were discarded.…”
Section: Referencesmentioning
confidence: 99%
See 2 more Smart Citations