Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting
DOI: 10.1109/ias.1988.25095
|View full text |Cite
|
Sign up to set email alerts
|

Programmed PWM techniques to eliminate harmonics-a critical evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
123
0
4

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 124 publications
(128 citation statements)
references
References 6 publications
1
123
0
4
Order By: Relevance
“…The cascaded multilevel inverter consists of a series of H-bridge inverter units [1]- [3]. Multilevel inverters also have several advantages with respect to hard-switched two-level pulse width-modulation (PWM) [4],adjustable-speed drives (ASDs). Motor damage and failure have been reported by industry as a result of some ASD inverters' high-voltage change rates (dv/dt), which produced a common-mode voltage across the motor windings.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The cascaded multilevel inverter consists of a series of H-bridge inverter units [1]- [3]. Multilevel inverters also have several advantages with respect to hard-switched two-level pulse width-modulation (PWM) [4],adjustable-speed drives (ASDs). Motor damage and failure have been reported by industry as a result of some ASD inverters' high-voltage change rates (dv/dt), which produced a common-mode voltage across the motor windings.…”
Section: Introductionmentioning
confidence: 99%
“…Fig. 3 have to be selected so that certain order harmonics are eliminated [4], [6], [8]. The multilevel inverter used is Asymmetrical with binary configuration where levels are identified using,…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, setting up an appropriate cooling method is a particularly serious issue, increasing in intricacy with machine size. Among various approaches for achieving optimal PWM, harmonic elimination method is predominant ( (Mohan et al, 1995), (Enjeti et al, 1990), (Sun et al, 1996), (Chiasson et al, 2004), (Czarkowski et al, 2002), (Sayyah et al, 2006c)). Since copper losses are fundamentally determined by current harmonics, defining a performance index related to undesirable effects of the harmonics is of the essence in lieu of focusing on specific harmonics (Bose, 2002).…”
Section: Introductionmentioning
confidence: 99%
“…The widely-used methods to control the output voltage of multilevel inverters include various multilevel sinusoidal PWM and space-vector PWM [8] - [9], but they increase control complexity and switching frequency. Another technique is called selective harmonic elimination (SHE) or programmed PWM [10].…”
mentioning
confidence: 99%