2018
DOI: 10.1007/978-3-030-01845-0_20
|View full text |Cite
|
Sign up to set email alerts
|

Progress Towards the Development of the DeTOP Hand Prosthesis: A Sensorized Transradial Prosthesis for Clinical Use

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…The Virtual Eggs Test is a modified version of the box and blocks test ( 53 ). It involves fragile blocks [i.e, “eggs”; ( 54 , 55 )]. The virtual eggs (40×40×40mm, ~80g) exploit a magnetic fuse mechanism which collapses (i.e., breaks) when grasped with a grip force larger than a specific threshold.…”
Section: Methodsmentioning
confidence: 99%
“…The Virtual Eggs Test is a modified version of the box and blocks test ( 53 ). It involves fragile blocks [i.e, “eggs”; ( 54 , 55 )]. The virtual eggs (40×40×40mm, ~80g) exploit a magnetic fuse mechanism which collapses (i.e., breaks) when grasped with a grip force larger than a specific threshold.…”
Section: Methodsmentioning
confidence: 99%
“…The virtual eggs test is a modified version of the box and blocks test 57 . It involves fragile blocks (that is, eggs 18,58 ). The virtual eggs (40 mm × 40 mm × 40 mm, ~80 g) exploit a magnetic fuse mechanism that collapses (that is, breaks) when grasped with a grip force larger than a specific threshold.…”
Section: Dexterity (Virtual Eggs Test)mentioning
confidence: 99%
“…The study was approved by the ethics board of the Scuola Superiore Sant'Anna (approval number 2/2017). The participant, a myoelectric hand regular user (male, 37 years old), was fitted with a research prosthesis including a custom socket, the wrist prototype assembled to an experimental multi-fingered hand (Mia Hand, Prensilia Srl, Italy) [6] and a battery. The socket included two surface EMG sensors (MyoBock 13E200, Ottobock, Germany) on antagonist muscles (wrist flexors/extensors) and a commercial quick-disconnect flange (9S266, Ottobock, Germany) for connection with the wrist.…”
Section: A Pilot Functional Testmentioning
confidence: 99%
“…The work of C.C. while new prosthetic components (artificial hands and control systems) became commercially available [3]- [5], or are approaching the market, such as the prosthetic hands Mia [6], Hannes [7], and SoftHand Pro-H [8]; and the control systems Complete Control and Myo Plus [5]. Nonetheless, these extraordinary advancements overlooked the peculiar biomechanical function of the wrist in a manipulation task.…”
Section: Introductionmentioning
confidence: 99%