2022
DOI: 10.1007/s00417-022-05851-y
|View full text |Cite
|
Sign up to set email alerts
|

Propensity-matched comparison of postoperative stability and visual outcomes of toric intraocular lens with or without a capsular tension ring and updated meta-analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 25 publications
0
3
0
Order By: Relevance
“…Previous investigations have demonstrated that ocular biological parameters, such as lens thickness (LT), anterior chamber depth (ACD), axial length (AL), and white-to-white distance (WTW), exhibit a negative correlation with the degree of postoperative rotation in toric IOL (10,19,20). In our study, we conducted subgroup analysis focusing on these parameters to assess their impact on rotational stability.…”
Section: Discussionmentioning
confidence: 98%
“…Previous investigations have demonstrated that ocular biological parameters, such as lens thickness (LT), anterior chamber depth (ACD), axial length (AL), and white-to-white distance (WTW), exhibit a negative correlation with the degree of postoperative rotation in toric IOL (10,19,20). In our study, we conducted subgroup analysis focusing on these parameters to assess their impact on rotational stability.…”
Section: Discussionmentioning
confidence: 98%
“…There is no definitive consensus regarding the ideal timing for CTR implantation. A recent meta-analysis has been conducted by our team ( 72 ), and it was demonstrated that the use of CTR significantly improves the rotational stability of toric IOLs by mitigating the influence of LT. Based on these findings, the co-implantation of CTR is strongly recommended for patients with LT of ≥4.5 mm, WTW of ≥11.6 mm, or high astigmatism.…”
Section: Interventions For Toric Iol Rotationmentioning
confidence: 99%
“…Moreover, this lens has been assessed in vitro 23 and used in keratoconic eyes with cataracts, 24–26 in combined vitrectomy, 27 can be repositioned after misalignment 28 or using a specific nomogram. 29 The different studies, with a variety of samples, that have reported clinical data in standard cataract surgery have shown good visual, refractive and rotational stability outcomes in the short- (1 month), 17–19 medium- (3 7 , 9–11 , 13 , 15 , 16 , 20–22 and 6 months 6 , 8 ) and long-term follow-up (12 months 14 ) for a general population, and specifically for myopic eyes. 8 , 16 However, to the best of our knowledge, up to March 2024 no clinical studies have been carried out to analyze this lens when implanted in hyperopic eyes.…”
Section: Introductionmentioning