Properties of crosslinked ultra-high-molecular-weight polyethylene

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
152
0
2

Year Published

2006
2006
2015
2015

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 239 publications
(157 citation statements)
references
References 46 publications
3
152
0
2
Order By: Relevance
“…However, as shown in Table, the amounts and sizes of particles have varied between the different studies (Howie et al 1988, Goodman 1994, Bobyn et al 1995, Dowd et al 1995, Frökjaer et al 1995, Goodman et al 1995, 1999, Kraemer et al 1995, Allen et al 1996, Aspenberg and Herbertsson 1996, Shanbhag et al 1997, Van Der Vis et al 1997, Kim et al 1998, Frökjaer et al 1999, Lalor et al 1999, Brooks et al 2000, Rahbek et al 2000, 2001, Bechtold et al 2001, Bi et al 2001b, Sundfeldt et al 2002. The time of introduction of the particles and the design of the studies also varied greatly.…”
Section: Particle Diseasementioning
confidence: 99%
See 3 more Smart Citations
“…However, as shown in Table, the amounts and sizes of particles have varied between the different studies (Howie et al 1988, Goodman 1994, Bobyn et al 1995, Dowd et al 1995, Frökjaer et al 1995, Goodman et al 1995, 1999, Kraemer et al 1995, Allen et al 1996, Aspenberg and Herbertsson 1996, Shanbhag et al 1997, Van Der Vis et al 1997, Kim et al 1998, Frökjaer et al 1999, Lalor et al 1999, Brooks et al 2000, Rahbek et al 2000, 2001, Bechtold et al 2001, Bi et al 2001b, Sundfeldt et al 2002. The time of introduction of the particles and the design of the studies also varied greatly.…”
Section: Particle Diseasementioning
confidence: 99%
“…Radiation sterilization of PE results in cross-linking, but recent research has focused on increasing the cross-linking and the wear resistance of PE by use of radiation of higher doses than used for sterilization (Lewis 2001). In vitro results have been promising, and a controlled randomized clinical 2-year follow-up study from our department evaluating cross-linked PE has demonstrated less penetration (measured by RSA), indicating less wear than conventional PE (Digas et al 2003).…”
Section: Polyethylenementioning
confidence: 99%
See 2 more Smart Citations
“…The second is a reaction of free radicals (produced by the breakage of the C-H bonds) with each other to form crosslinks between adjacent molecule chains (Fig. 1b) [55].…”
Section: Radiationmentioning
confidence: 99%