“…The ST is an initial test of the sealers and could serve as a parameter for other tests; results may vary according to the components and particle size of the tested material, ambient temperature, and RH. 3,18,24,25,26,27 The DC test showed higher values for GutaFlow 2 (−26.06% ± 1.24%) and GutaFlow Bioseal (2.10% ± 1.47 %) in comparison with those for MM Seal (8.47% ± 2.41%) and AH Plus (0.06% ± 0.12%), possibly due to the polymer reaction between bisphenol A and F resins, which promote a closer and more rigid structure through hydrogen bonds and allow the adsorption of water after polymerization. 1, 3,5,6,7,8,9,13,14,15,16,21,23 GuttaFlow 2 showed a significant loss of sample mass, likely because of the presence of gutta-percha and silver nanoparticles, which confer greater stability to the polymer matrix due to attractive forces and cross-linking between molecules.…”