2016
DOI: 10.1016/j.joen.2016.06.002
|View full text |Cite
|
Sign up to set email alerts
|

Properties of Tricalcium Silicate Sealers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

14
112
4
20

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 127 publications
(150 citation statements)
references
References 20 publications
14
112
4
20
Order By: Relevance
“…These efficiencies are clinically favourable characteristics and their mechanical advantages are proved in previous studies (11,32). According to the manufacturers' introduction of brand new shaping instruments such as Self Adjusting File (ReDent Nova, Ra'anana, Israel), TruShape (Dentsply Tulsa Dental Specialities) and XP endo-Shaper (FKG, La Chaux-de-Fonds, Switzerland), these brand new instruments were developed to preserve natural canal shape as much as possible to keep root dentin integrity.…”
Section: Discussionmentioning
confidence: 68%
“…These efficiencies are clinically favourable characteristics and their mechanical advantages are proved in previous studies (11,32). According to the manufacturers' introduction of brand new shaping instruments such as Self Adjusting File (ReDent Nova, Ra'anana, Israel), TruShape (Dentsply Tulsa Dental Specialities) and XP endo-Shaper (FKG, La Chaux-de-Fonds, Switzerland), these brand new instruments were developed to preserve natural canal shape as much as possible to keep root dentin integrity.…”
Section: Discussionmentioning
confidence: 68%
“…The opacifier however varies between them (zirconium oxide in MTA Angelus but tantalum oxide in NeoMTA Plus) as detected in XRD. Recently, the biocompatible zirconium or tantalum is added to the root repair materials as radiopacifier instead of barium sulfate to eliminate the coronal tooth discoloration [33]. Other elements as sulfur, indicating the presence of gypsum (calcium sulfate) phase of Portland cement [1], have also been detected from EDX.…”
Section: Discussionmentioning
confidence: 99%
“…The ST is an initial test of the sealers and could serve as a parameter for other tests; results may vary according to the components and particle size of the tested material, ambient temperature, and RH. 3,18,24,25,26,27 The DC test showed higher values for GutaFlow 2 (−26.06% ± 1.24%) and GutaFlow Bioseal (2.10% ± 1.47 %) in comparison with those for MM Seal (8.47% ± 2.41%) and AH Plus (0.06% ± 0.12%), possibly due to the polymer reaction between bisphenol A and F resins, which promote a closer and more rigid structure through hydrogen bonds and allow the adsorption of water after polymerization. 1, 3,5,6,7,8,9,13,14,15,16,21,23 GuttaFlow 2 showed a significant loss of sample mass, likely because of the presence of gutta-percha and silver nanoparticles, which confer greater stability to the polymer matrix due to attractive forces and cross-linking between molecules.…”
Section: 4621mentioning
confidence: 99%