We reviewed the literature on obstetric failed tracheal intubation from 1970 onwards. The incidence remained unchanged over the period at 2.6 (95% CI 2.0 to 3.2) per 1000 anaesthetics (1 in 390) for obstetric general anaesthesia and 2.3 (95% CI 1.7 to 2.9) per 1000 general anaesthetics (1 in 443) for caesarean section. Maternal mortality from failed intubation was 2.3 (95% CI 0.3 to 8.2) per 100000 general anaesthetics for caesarean section (one death per 90 failed intubations). Maternal deaths occurred from aspiration or hypoxaemia secondary to airway obstruction or oesophageal intubation. There were 3.4 (95% CI 0.7 to 9.9) front-of-neck airway access procedures (surgical airway) per 100000 general anaesthetics for caesarean section (one procedure per 60 failed intubations), usually carried out as a late rescue attempt with poor maternal outcomes. Before the late 1990s, most cases were awakened after failed intubation; since the late 1990s, general anaesthesia has been continued in the majority of cases. When general anaesthesia was continued, a laryngeal mask was usually used but with a trend towards use of a second-generation supraglottic airway device. A prospective study of obstetric general anaesthesia found that transient maternal hypoxaemia occurred in over two-thirds of cases of failed intubation, usually without sequelae. Pulmonary aspiration occurred in 8% but the rate of maternal intensive care unit admission after failed intubation was the same as that after uneventful general anaesthesia. Poor neonatal outcomes were often associated with preoperative fetal compromise, although failed intubation and lowest maternal oxygen saturation were independent predictors of neonatal intensive care unit admission.
We reviewed the literature on obstetric failed tracheal intubation from 1970 onwards. The incidence remained unchanged over the period at 2.6 (95% CI 2.0 to 3.2) per 1000 anaesthetics (1 in 390) for obstetric general anaesthesia and 2.3 (95% CI 1.7 to 2.9) per 1000 general anaesthetics (1 in 443) for caesarean section. Maternal mortality from failed intubation was 2.3 (95% CI 0.3 to 8.2) per 100000 general anaesthetics for caesarean section (one death per 90 failed intubations). Maternal deaths occurred from aspiration or hypoxaemia secondary to airway obstruction or oesophageal intubation. There were 3.4 (95% CI 0.7 to 9.9) front-of-neck airway access procedures (surgical airway) per 100000 general anaesthetics for caesarean section (one procedure per 60 failed intubations), usually carried out as a late rescue attempt with poor maternal outcomes. Before the late 1990s, most cases were awakened after failed intubation; since the late 1990s, general anaesthesia has been continued in the majority of cases. When general anaesthesia was continued, a laryngeal mask was usually used but with a trend towards use of a second-generation supraglottic airway device. A prospective study of obstetric general anaesthesia found that transient maternal hypoxaemia occurred in over two-thirds of cases of failed intubation, usually without sequelae. Pulmonary aspiration occurred in 8% but the rate of maternal intensive care unit admission after failed intubation was the same as that after uneventful general anaesthesia. Poor neonatal outcomes were often associated with preoperative fetal compromise, although failed intubation and lowest maternal oxygen saturation were independent predictors of neonatal intensive care unit admission.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.