2020
DOI: 10.1016/j.forc.2020.100252
|View full text |Cite
|
Sign up to set email alerts
|

Proposed practices for validating the performance of instruments used for automated inorganic gunshot residue analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 8 publications
0
10
0
Order By: Relevance
“…Innovations in instrument technology, automatisation of analysis, improvements in image processing and EDS spectra treatment software, as well as statistical approaches enlarged the possibility of SEM/EDS analysis and significance of interpretation of the obtained data [3,4]. However, strict monitoring of instrument sub-system performance and method validation to demonstrate the whole system behavior needed in order to guarantee the reliability of inorganic gunshot residue (iGSR) results presented in front of the justice authorities [13]. Brozek-Muncha [6] demonstrated that SEM/EDS data could be used more comprehensively for study the relationship between chemical and morphological properties of GSR particles, source and mechanism of their formation.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Innovations in instrument technology, automatisation of analysis, improvements in image processing and EDS spectra treatment software, as well as statistical approaches enlarged the possibility of SEM/EDS analysis and significance of interpretation of the obtained data [3,4]. However, strict monitoring of instrument sub-system performance and method validation to demonstrate the whole system behavior needed in order to guarantee the reliability of inorganic gunshot residue (iGSR) results presented in front of the justice authorities [13]. Brozek-Muncha [6] demonstrated that SEM/EDS data could be used more comprehensively for study the relationship between chemical and morphological properties of GSR particles, source and mechanism of their formation.…”
Section: Discussionmentioning
confidence: 99%
“…A standard sample Plano SPS-5P-2A, originated from the proficiency testing GSR 2005 PT by ENFSI GSR 2005 PT [14] was used as a positive control. In order to assure minimal rate of false negative results and to control the optimal instument operating parameters [13], the positive control sample was scanned before each sample till at least one particle, containing PbBaSb with a dimeter 1 µm was identified. Blank sample was used to monitor laboratory environment or cross-contamination and to asure minimal rate of FP results.…”
Section: Internal Quality Control and Methods Performancementioning
confidence: 99%
See 3 more Smart Citations