Prospective Follow-Up of Cortical Interruptions, Bone Density, and Micro-structure Detected on HR-pQCT: A Study in Patients with Rheumatoid Arthritis and Healthy Subjects

Abstract: Objectives The purpose of the study was to prospectively investigate change (repair or progression) in the number, surface area and volume of cortical interruptions, bone density (vBMD) and micro-structural parameters assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT) in finger joints of patients with rheumatoid arthritis (RA) treated with synthetic disease modifying anti-rheumatic drugs (sDMARDs) and/or biologic DMARDs (bDMARDs) over a 1-year follow-up period, and in comparison … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
22
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(22 citation statements)
references
References 31 publications
0
22
0
Order By: Relevance
“…Erosions are most abundant in patients with RA (3,4,16,33,52,54,55,57,64,65,69), especially ACPA and rheumatoid factor (RF) positive RA patients (26). The erosions exhibit a clear predilection for the radial and ulnar quadrant of the 2nd and 3rd MCP joints.…”
Section: Erosion Detection By Hr-pqctmentioning
confidence: 99%
See 3 more Smart Citations
“…Erosions are most abundant in patients with RA (3,4,16,33,52,54,55,57,64,65,69), especially ACPA and rheumatoid factor (RF) positive RA patients (26). The erosions exhibit a clear predilection for the radial and ulnar quadrant of the 2nd and 3rd MCP joints.…”
Section: Erosion Detection By Hr-pqctmentioning
confidence: 99%
“…However, manual scoring is laborious and requires substantial training and standardization. An automated detection algorithm has been developed, named the Cortical Interruption Detection Algorithm (39,40,52,53,64). The Cortical Interruption Detection Algorithm detects the presence of cortical interruptions, directing the reader to lesion locations to verify that they meet the erosion definition as opposed to those that merely represent physiological breaks in the cortical bone, i.e., vascular channels ( Figure 4A) or stack misalignment ( Figure 4B) and osteophyte formation ( Figure 4C).…”
Section: Erosion Detection By Hr-pqctmentioning
confidence: 99%
See 2 more Smart Citations
“…These artifacts may increase the difficulty in analyzing bone erosions that span two stacks by causing a misalignment, thereby impacting determination of the erosion volume, and potentially impacting the assessment of the presence of an erosion. Prior studies have addressed this issue by only analyzing erosions contained within a single stack, or by discarding scans with stack shift artifacts [14][15][16]. In a study that proposes an automated method for quantifying longitudinal changes in erosions using 3D registration, 43% of HR-pQCT scans of the MCP joints had to be excluded due to severe motion artifact [6].…”
Section: Introductionmentioning
confidence: 99%