2022
DOI: 10.1038/s43856-022-00102-x
|View full text |Cite
|
Sign up to set email alerts
|

Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms

Abstract: Background Measuring vital signs plays a key role in both patient care and wellness, but can be challenging outside of medical settings due to the lack of specialized equipment. Methods In this study, we prospectively evaluated smartphone camera-based techniques for measuring heart rate (HR) and respiratory rate (RR) for consumer wellness use. HR was measured by placing the finger over the rear-facing camera, while RR was measured via a video of th… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 51 publications
0
9
0
Order By: Relevance
“…Mean absolute error (MAE) was used to assess HR and RR performance for multiwavelength PPG and BioZ relative to SS-ECG (ground truth). Following prior work [7], HR was considered to be in agreement with ground truth if within 5 beats/minute (MAE), and RR if within 1 breath/min (MAE).…”
Section: Performance Evaluation Metricsmentioning
confidence: 99%
“…Mean absolute error (MAE) was used to assess HR and RR performance for multiwavelength PPG and BioZ relative to SS-ECG (ground truth). Following prior work [7], HR was considered to be in agreement with ground truth if within 5 beats/minute (MAE), and RR if within 1 breath/min (MAE).…”
Section: Performance Evaluation Metricsmentioning
confidence: 99%
“…Different sources of light can be used according to the purpose. For example, even smartphones flash as a light source and the camera as a detector has shown to reliably measure heart rate [ 90 ]. Pulse oximeters usually use two light-emitting diodes that emit light at the 660 nm (red) and the 940 nm (near-infrared) wavelengths as a light source [ 91 ].…”
Section: Emerging Technologiesmentioning
confidence: 99%
“…Further, respiratory system malfunction can produce physical breathing disorders including pulmonary diseases and sleep apnea. RR may also be an ideal biomarker due to its measurability using mobile devices such as wearables 12 , 13 , smart phones 14 , wrist-wearables 15 , chest bands 16 , and wireless home devices 17 .…”
Section: Introductionmentioning