2018
DOI: 10.1007/s00261-018-1804-9
|View full text |Cite
|
Sign up to set email alerts
|

Prostate MRI using an external phased array wearable pelvic coil at 3T: comparison with an endorectal coil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
17
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(27 citation statements)
references
References 25 publications
2
17
0
Order By: Relevance
“…Analysis of the individual sequences revealed a pooled preference for the FSC in T2WI and for the ERC in DWI. These results are in agreement with the studies by Barth et al [9] and O'Donohoe et al, [13] who compared the quality of T2WI and DWI obtained with an ERC to those acquired using a pelvic phased-array coil or a wearable pelvic coil that seats nearer to the prostate, respectively. In both studies the overall quality was similar for the coils that were compared, but with a tendency for better DWI obtained using the ERC.…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…Analysis of the individual sequences revealed a pooled preference for the FSC in T2WI and for the ERC in DWI. These results are in agreement with the studies by Barth et al [9] and O'Donohoe et al, [13] who compared the quality of T2WI and DWI obtained with an ERC to those acquired using a pelvic phased-array coil or a wearable pelvic coil that seats nearer to the prostate, respectively. In both studies the overall quality was similar for the coils that were compared, but with a tendency for better DWI obtained using the ERC.…”
Section: Discussionsupporting
confidence: 92%
“…These findings may reflect the fact that ERC MR images are generally prone to signal inhomogeneity due to the non-uniform reception profile [11], susceptibility artifacts as a result of the direct interface of soft tissue and air or liquids in the ERC, and anatomical distortion [28]. These observations have been confirmed by several published studies [9,10,13]. Different correction algorithms have been developed to compensate signal inhomogeneity, but these may lead to noise level variation and an increase of acquisition time [11,12,29].…”
Section: Discussionmentioning
confidence: 67%
See 1 more Smart Citation
“…Explored solutions have included bowel preparation and antispasmotic agents such as glucagon . While use of an endorectal coil for prostate MRI helps to minimize gas within the rectum and decreases distance from coil to the prostate gland, which greatly increases the signal‐to‐noise ratio (SNR), the endorectal coil itself has been shown to cause susceptibility artifact . These methods increase the time involved for patients, physicians, and support staff alike, and introduce patient discomfort.…”
mentioning
confidence: 99%
“…The impact of multiparametric MRI has been evaluated in several studies and meta-analyzes. A sensitivity up to 96% and a specificity up to 88% have been re- search before they could be recommended [35].…”
Section: Other Groups Resultsmentioning
confidence: 99%