2019
DOI: 10.1016/j.bspc.2019.101588
|View full text |Cite
|
Sign up to set email alerts
|

Prosthetic hand control: A multidisciplinary review to identify strengths, shortcomings, and the future

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
27
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 59 publications
(28 citation statements)
references
References 82 publications
1
27
0
Order By: Relevance
“…Furthermore, the RMSE when using the EMG alone was 0.57 ± 0.07 Nm for the training dataset and 0.73 ± 0.11 Nm for the test dataset [73]. Therefore, using the EMG and the kinematic data as inputs for estimating the torque showed better performance [79]. To conclude, EMG-driven robots are considered the better choice to rehabilitate impaired limbs when compared to normal robots [8].…”
Section: Resultsmentioning
confidence: 90%
See 1 more Smart Citation
“…Furthermore, the RMSE when using the EMG alone was 0.57 ± 0.07 Nm for the training dataset and 0.73 ± 0.11 Nm for the test dataset [73]. Therefore, using the EMG and the kinematic data as inputs for estimating the torque showed better performance [79]. To conclude, EMG-driven robots are considered the better choice to rehabilitate impaired limbs when compared to normal robots [8].…”
Section: Resultsmentioning
confidence: 90%
“…The study involved recruiting six healthy subjects with three different loads (0 kg, 1 kg and 2 kg) held by the hand at two different positions: elbow flexion (90 • ) and full elbow extension (0 • ). The approach was performed at two different angular velocities (60 • /s and 90 • /s) [79]. The subjects were trained to perform the aforementioned procedure, and the root mean square error (RMSE) was calculated between the expected and the predicted torques for each procedure.…”
Section: Resultsmentioning
confidence: 99%
“…Unfortunately, the cost of such devices is one of the major constraints in its popularization. The commercially available prosthetic devices range from $15000 to 100000 or even higher if additional customization is required [ 86 ]. Several research groups have worked for the development of low-cost prosthetic devices but they lack in their real-life application and catering to the customer need.…”
Section: Application Of Iot-aided Robotic Technology In Healthcarementioning
confidence: 99%
“…This fact occurred for all classifiers, feature sets, and overlap rates. As mentioned before, in works related to sEMG pattern recognition, the window length directly affected the accuracies [17,65,66]. However, the window size cannot be too extensive or large and thus compromise the whole application (involving the detection of sEMG and the final response of the actuation).…”
Section: Influence Of Segmentation Parametersmentioning
confidence: 99%