2014
DOI: 10.1016/j.jcjo.2013.10.001
|View full text |Cite
|
Sign up to set email alerts
|

Prosthetic iris devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
66
0
16

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 84 publications
(82 citation statements)
references
References 41 publications
0
66
0
16
Order By: Relevance
“…Most cases of aniridia occur after severe ocular trauma, less common causes are congenital, ICE-syndrome, or an iatrogenic iris defect. While small defects can be repaired with specific suture techniques [1], more complex cases require an iris prosthesis [2,3]. Due to limited flexibility of the iris tissue, better iris implants have evolved over the last decade with soft and foldable material for easy and minimal invasive implantation and with enough structural stability for suturing [4].…”
Section: Introductionmentioning
confidence: 99%
“…Most cases of aniridia occur after severe ocular trauma, less common causes are congenital, ICE-syndrome, or an iatrogenic iris defect. While small defects can be repaired with specific suture techniques [1], more complex cases require an iris prosthesis [2,3]. Due to limited flexibility of the iris tissue, better iris implants have evolved over the last decade with soft and foldable material for easy and minimal invasive implantation and with enough structural stability for suturing [4].…”
Section: Introductionmentioning
confidence: 99%
“…1 However, a newer trend has been the implantation of these devices for purely cosmetic purposes. Figure 1 features a PID called NewColorIris, which has been associated with serious postimplant complications in several published reports.…”
Section: Discussionmentioning
confidence: 99%
“…4 With a poor fit, the increased mobility of the implant may result in mechanical trauma to the corneal endothelium and angle structures. 1 Increased IOP may also result from the semicircular flaps on the implant directly impinging on the trabecular meshwork. Pigment dispersion and PAS are among other potentiating factors for increased IOP.…”
Section: Discussionmentioning
confidence: 99%
“…The implants are used to treat congenital and acquired aniridia, ocular albinism, iris coloboma, and other iris defects. 1 In 2004, a silicone anterior chamber, anglesupported implant, the Newcoloriris (Kahn Medical Implants), was described for treatment of oculocutaneous albinism. A It has subsequently been marketed in Panama for cosmetic alteration of the iris color.…”
Section: Online Videomentioning