1942
DOI: 10.6028/jres.029.008
|View full text |Cite
|
Sign up to set email alerts
|

Provisional pH values for certain standard buffer solutions

Abstract: For use in the calibration of electrometric pH assemblies, 17 standard buffer solutions have been investigated, and pH values at 20°, 25°. and 30° C have been assigned to them. The pH values of these solutions range from 2.27 to 11.68 and are considered accurate to ± 0.02 pH unit.Hydrogen-silver-chloride cells without liquid junctions were used for establishing the precise pH values of the buffer mixtures. The assumptions made to determine the activity coefficients of the ions in the mixt ures are discussed. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
39
0

Year Published

1943
1943
2012
2012

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 32 publications
(39 citation statements)
references
References 4 publications
0
39
0
Order By: Relevance
“…The calculation of the second dissociation constant, K 2 , of a weak acid and the pH values of solutions of the acid mixed with its salts from emf measurements of hydrogen-silver-chloride cells has been outlined in earlier publications from this Bureau [2,6,7] . Mention should be made, however, of the assumptions upon which these calculations are based.…”
Section: Discussion Of the Ele Ctromotive-force Meth Odmentioning
confidence: 99%
See 2 more Smart Citations
“…The calculation of the second dissociation constant, K 2 , of a weak acid and the pH values of solutions of the acid mixed with its salts from emf measurements of hydrogen-silver-chloride cells has been outlined in earlier publications from this Bureau [2,6,7] . Mention should be made, however, of the assumptions upon which these calculations are based.…”
Section: Discussion Of the Ele Ctromotive-force Meth Odmentioning
confidence: 99%
“…= (E-EO)/k+ log (mRPSmc,/mps) +2A-l""p'/( 1 + Bar/j;) (7) It is usually possible to choose a value of at that will make pK; a linear fun ction of J.I. The slope of the plot of pK; with r espect to J. l .…”
Section: Discussion Of the Ele Ctromotive-force Meth Odmentioning
confidence: 99%
See 1 more Smart Citation
“…PtjH2jH+, Cl-jAgCljAg, (1) where H+ and Cl-represent the components of the cell electrolyte to which the cell is reversible. The emf of the cell at a centigrade temperature, t, is related to its standard potential, EO, and to the activities, a , of these two ions by the equation…”
Section: Titration Curves At Constant Ionic Strength From Cells W Ithmentioning
confidence: 99%
“…from the emf measurements of such a cell often involve considerable uncertainty, and in unfavorable cases they may be in error by more than 0.05 pH unit [1,2]. 1 The principal reason for this difficulty is neglect of the contribution of the potential at the liquid junction or in the application of improper or inadequate corrections for it. Such corrections are laborious and unsatisfactory and require a knowledge, often unavailable, of the mobilities and activities of the ions of which the solutions are composed.…”
mentioning
confidence: 99%