Proximal balloon-guided catheter with flow inversion vs. distal filter protection during the carotid stent placement, a seven years experience in a Colombian reference center

Abstract: Background and purpose The carotid stent placement as a therapeutic option for carotid stenosis has been increasing among years; therefore, studies are required to evaluate the security and efficacy of its materials. The purpose of this study was to evaluate the distal filter and the proximal balloon-guided catheter with flow inversion as protection devices during carotid angioplasty and stenting. Methods This is a retrospective, observational study of patients diagnosed with carotid stenosis treated with angi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
1
0
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 16 publications
0
1
0
1
Order By: Relevance
“…The consistent use of filter systems in American CAS studies (CREST, ACT-1), years of good experiences, and standardized ap-plication with corresponding interventionalist training support use of such systems. Balloon catheters for temporary closure of the external and internal carotid arteries or flow reversal catheters with additional connection to the femoral vein can ensure protection against embolic complications similar to filter systems [26]. Due to the limited availability and limitations regarding the inner lumen, they were not used in our study.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The consistent use of filter systems in American CAS studies (CREST, ACT-1), years of good experiences, and standardized ap-plication with corresponding interventionalist training support use of such systems. Balloon catheters for temporary closure of the external and internal carotid arteries or flow reversal catheters with additional connection to the femoral vein can ensure protection against embolic complications similar to filter systems [26]. Due to the limited availability and limitations regarding the inner lumen, they were not used in our study.…”
Section: Discussionmentioning
confidence: 99%
“…Für die Verwendung von Filtersystemen sprachen deren konsequente Verwendung in amerikanischen CAS-Studien (CREST, ACT-1), jahrelange gute Erfahrungen und die standardisierte Handhabung mit entsprechendem Training der Interventionalisten. Ballonführungskatheter zum temporären Verschluss der ACE und ACI oder Flussumkehrkatheter mit zusätzlicher Verbindung zur V. femoralis können ähnlich wie Filtersysteme einen Schutz gegen embolische Komplikationen gewährleisten [26]. Aufgrund der eingeschränkten Verfügbarkeit und Limitierungen bezüglich des Innenlumens wurden sie im Rahmen unserer Studie nicht verwendet.…”
Section: Diskussionunclassified