2005
DOI: 10.3928/0147-7447-20050902-05
|View full text |Cite
|
Sign up to set email alerts
|

Proximal/Distal Mismatch: Type A and C Femurs

Abstract: Femoral deformity in primary total hip arthroplasty can make restoration of joint biomechanics difficult. The S-ROM (DePuy Orthopaedics Inc., Warsaw, lnd) prosthesis' modular design allows for independent matching of diaphyseal and metaphyseal anatomy. Corrective osteotomy may also be performed because the stem achieves both proximal and distal stability, which resists the micromotion and torsional loads that would otherwise prevent ingrowth. Seventy-three hips were reviewed at a minimum of 10 years' follow-up… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(2 citation statements)
references
References 12 publications
0
1
0
1
Order By: Relevance
“…No obstante, el potencial stress shielding permanece latente y podría causar una deficiencia masiva de capital óseo femoral, lo que hace que la cirugía de revisión sea un nuevo desafío en el futuro. 73,74 En este sentido, se han diseñado componentes femorales modulares alternativos con recubrimiento proximal y fijación metafisaria, como el S-ROM (DePuy). Aunque este implante permite una adecuada reconstrucción al combinar la anatomía proximal distal, tiene el problema de la modularidad.…”
Section: A B Cunclassified
“…No obstante, el potencial stress shielding permanece latente y podría causar una deficiencia masiva de capital óseo femoral, lo que hace que la cirugía de revisión sea un nuevo desafío en el futuro. 73,74 En este sentido, se han diseñado componentes femorales modulares alternativos con recubrimiento proximal y fijación metafisaria, como el S-ROM (DePuy). Aunque este implante permite una adecuada reconstrucción al combinar la anatomía proximal distal, tiene el problema de la modularidad.…”
Section: A B Cunclassified
“…Standard-length stems were frequently applied in Dorr type C femurs in previous studies. However, some limitations of standard-length cementless stems, such as proximal–distal mismatch 2 , more intraoperative fractures 3 , and loss of bone stock in revision, are highlighted in Dorr type C femurs, which led to our exploration of short cementless stems. Short stems offer specific advantages, including better bone preservation, avoidance of proximal–distal mismatch, lower rates of intraoperative fracture 4 , natural load transfer 5 , smaller incisions, and less stress shielding, and bone resorption 6 .…”
Section: Introductionmentioning
confidence: 99%