2017
DOI: 10.1016/j.jmig.2017.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Proximal Tubal Patency Demonstrated Through Air Infusion During Flexible Office Hysteroscopy Is Predictive of Whole Tubal Patency

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
57
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(60 citation statements)
references
References 7 publications
2
57
1
Order By: Relevance
“…The results of our study are in agreement with two previous studies which evaluated the accuracy of diagnostic hysteroscopic bubble test in detection of tubal patency . 12,3 Parry conducted a prospective study to determine if air bubbles filled with saline during flexible diagnostic hysteroscopy will accurately predict tubal patency. The authors reported that the hysteroscopic approach has 98.3% sensitivity and 83.7% specificity in detection of tubal patency.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The results of our study are in agreement with two previous studies which evaluated the accuracy of diagnostic hysteroscopic bubble test in detection of tubal patency . 12,3 Parry conducted a prospective study to determine if air bubbles filled with saline during flexible diagnostic hysteroscopy will accurately predict tubal patency. The authors reported that the hysteroscopic approach has 98.3% sensitivity and 83.7% specificity in detection of tubal patency.…”
Section: Discussionmentioning
confidence: 99%
“…The authors reported that the hysteroscopic approach has 98.3% sensitivity and 83.7% specificity in detection of tubal patency. 12 A prospective study including 85 infertile patients compared the diagnostic accuracy of diagnostic hysteroscopy bubble test with HSG and laparoscopy. In 78 cases (91.7 %) the diagnostic hysteroscopic bubble test was feasible.…”
Section: Discussionmentioning
confidence: 99%
“…With or without using Doppler techniques, 3D-HyFoSy does not seem to offer benefits above real-time 2D-HyFoSy performed by an ultrasonographer who is familiar with pelvic anatomy (Figure 1). The clear white line indicating foam passage through the proximal part of the tube is sufficient evidence for the absence of a distal occlusion as is known from studies using hysteroscopy and air bubbles [25]. Anyway, from the nine clinical studies [1524], it can be concluded that HyFoSy appears to be accurate and well-tolerated first-line diagnostic procedure and the 3D-HyFoSy technique is helpful for a less experienced operator.…”
Section: 3-dimensional Ultrasound and Doppler Flow Techniquesmentioning
confidence: 87%
“…Inclusion criteria encompassed articles in the English language with the primary topic being diagnostic accuracy of hysteroscopic methods for evaluation of Fallopian tube patency. Four relevant articles were identified [4,5,7,8]. See ▶ Table 1 for an overview about reviewed studies.…”
Section: Methodsmentioning
confidence: 99%
“…A comparable technique was used in a recently published prospective study. Parry et al evaluated the accuracy of an air-bubbling ("Parryscope technique") effect during the flow of the hysteroscopic fluid through the ostia, provoked by an air-infusion into the uterine cavity [8]. The technique enabled the researchers to provide an even more precise statement about tubal patency.…”
Section: The Value Of Hysteroscopic Visualization Of the Fallopian Tumentioning
confidence: 99%