PS-1/S1 picosecond streak camera application for multichannel laser system diagnostics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…In order to overcome this limitation, we decided to use, for SR diagnostics, streak image tubes of PIF-01/S1 type, which were developed and have been continuously manufactured at the Photoelectronics Department of A. M. Prokhorov General Physics Institute since the eighties [7]. The experimentally proved limited temporal resolution of such tubes approaches 1±0.2 ps in a single streak mode at 2•10 10 cm/s streak speed and 3 kV/mm electric field strength near the photocathode surface, when femtosecond laser pulses illuminate the tube-input photocathode at 800 and 911 nm wavelength [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…In order to overcome this limitation, we decided to use, for SR diagnostics, streak image tubes of PIF-01/S1 type, which were developed and have been continuously manufactured at the Photoelectronics Department of A. M. Prokhorov General Physics Institute since the eighties [7]. The experimentally proved limited temporal resolution of such tubes approaches 1±0.2 ps in a single streak mode at 2•10 10 cm/s streak speed and 3 kV/mm electric field strength near the photocathode surface, when femtosecond laser pulses illuminate the tube-input photocathode at 800 and 911 nm wavelength [8,9].…”
Section: Introductionmentioning
confidence: 99%
“…4 (c) ), six individual longitudinal modes were clearly resolved and were separated by a mode spacing of ~11 GHz. The laser output pulse energy (~1 pJ) was insufficient to permit measurement of the pulse duration by autocorrelation method so we employed a high-speed optoelectronic streak camera PS-1/S1 29 with a 1-ps temporal resolution. The measured streak-camera trace and corresponding sech 2 (t) fit are shown in Fig.…”
Section: Lasing Experiments and Resultsmentioning
confidence: 99%
“…After the amplification the pulse energy approached 30 mJ with a repetition rate 2 Hz, and the radiation polarisation was vertical. The pulse duration was measured using a PS-1/S1 streak camera [29,30], developed and fabricated at the General Physics Institute, Russian Academy of Sciences. In the streak camera the electro-optical converter (EOC) with a silver - oxygencaesium photocathode was used.…”
Section: Methodsmentioning
confidence: 99%