Abstract:Horizontally lying headed studs allow thin concrete slabs as a concrete flange. The shear capacity of studs close to the concrete edge is affected by splitting forces in the concrete. Due to the small edge distance of the headed studs to the concrete edge, a reduction in the capacity of the shear connection according to EN 1994-2 Annex C is required. Thereby additional geometric boundary conditions for the required length of the headed studs in the edge position are defined. In this way, a pull-out failure, wh… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.