2019
DOI: 10.3390/app9040658
|View full text |Cite
|
Sign up to set email alerts
|

Pullout Response of Ultra-High-Performance Concrete with Twisted Steel Fibers

Abstract: This paper aims to develop a pullout force formula and increase the understanding of the damage mechanisms of ultra-high-performance fiber reinforced concrete (UHPFRC) with twisted steel fibers (TSFs) through a pull-out test and finite element analysis (FEA). The formula was first obtained through a theoretical force analysis with model assumptions that are based on the experimental data in the literature. A microscale in-situ X-ray computed tomography (µXCT) was used to prepare 3D images of the cross-section … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…To examine the morphology of the PVA fiber bundles after the specimens were formed, MXCT was performed using the Nikon XTH320 MXCT facility at Zhejiang University, Hangzhou, China, as shown in Figure 5b. The scanning parameters used included an exposure time of 500 ms, a voltage of 200 kV, a current of 100 µA, and a scanning accuracy of approximately 30 µm [40]. Image processing was performed using VGStudio MAX 3.0 software, and 2D slices and 3D solid images were obtained by reconstructing the data from the original MXCT data.…”
Section: Specimensmentioning
confidence: 99%
See 1 more Smart Citation
“…To examine the morphology of the PVA fiber bundles after the specimens were formed, MXCT was performed using the Nikon XTH320 MXCT facility at Zhejiang University, Hangzhou, China, as shown in Figure 5b. The scanning parameters used included an exposure time of 500 ms, a voltage of 200 kV, a current of 100 µA, and a scanning accuracy of approximately 30 µm [40]. Image processing was performed using VGStudio MAX 3.0 software, and 2D slices and 3D solid images were obtained by reconstructing the data from the original MXCT data.…”
Section: Specimensmentioning
confidence: 99%
“…Buildings 2023, 13, x FOR PEER REVIEW 6 of approximately 30 µm [40]. Image processing was performed using VGStudio MA software, and 2D slices and 3D solid images were obtained by reconstructing the from the original MXCT data.…”
Section: Specimens Bundles Twist Factormentioning
confidence: 99%