1997
DOI: 10.1046/j.1469-0705.1997.10010027.x
|View full text |Cite
|
Sign up to set email alerts
|

Pulmonary venous blood flow in the human fetus

Abstract: The objective of this study was to assess the feasibility of recording pulmonary venous blood flow in the human fetus, and to evaluate its relationship with gestational age. We studied 152 singleton pregnancies between the 19th and 40th weeks of gestation. One hundred and one cases were studied cross-sectionally to gather data on color flow visualization, and 51 were studied longitudinally. The upper right pulmonary vein was interrogated by pulsed wave Doppler to assess pulmonary venous blood flow. On color Do… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

3
30
2

Year Published

2001
2001
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(35 citation statements)
references
References 0 publications
3
30
2
Order By: Relevance
“…Our data demonstrate that PVD indices are both accurate and reproducible, with mean intraobserver and interobserver differences comparable to previous studies of PVD in both the fetus 30 and the adult. 31 However, there is modest variability in measurement of PVD indices, particularly with regard to the estimate of PVD A-wave magnitude, and therefore, PVD findings should be interpreted in the clinical setting with this foreknowledge.…”
Section: Table 3 Clinical Accuracy Of Pvd Doppler Indices In Predictsupporting
confidence: 85%
See 1 more Smart Citation
“…Our data demonstrate that PVD indices are both accurate and reproducible, with mean intraobserver and interobserver differences comparable to previous studies of PVD in both the fetus 30 and the adult. 31 However, there is modest variability in measurement of PVD indices, particularly with regard to the estimate of PVD A-wave magnitude, and therefore, PVD findings should be interpreted in the clinical setting with this foreknowledge.…”
Section: Table 3 Clinical Accuracy Of Pvd Doppler Indices In Predictsupporting
confidence: 85%
“…Although in normal fetuses, PVD S-and D-wave velocities increase throughout gestation, and the S/D ratio and A-wave magnitude remain unchanged, 30 further work is needed to confirm the predictive capabilities of second-trimester PVD assessment in this population.…”
Section: Table 3 Clinical Accuracy Of Pvd Doppler Indices In Predictmentioning
confidence: 97%
“…With the advent of color Doppler, tiny vessels became visible and thus reliably accessible to spectral Doppler evaluation. Reports emerged on pulmonary arterial and venous flow, on measurements across the fetal shunts such as the ductus arteriosus and foramen ovale, and even on the coronary artery and venous systems 37,[41][42][43][44][45][46][47][48][49][50] . The quantification of tricuspid valve insufficiency was shown to reveal valuable information on etiology and prognosis [51][52][53][54] .…”
Section: Spectral Dopplermentioning
confidence: 99%
“…Advances in molecular genetics and the use of invasive interventions, such as fetal skin biopsy, have enabled prenatal diagnosis 7 . Recent advances in threedimensional ultrasonography have enabled non-invasive prenatal diagnosis of congenital ichthyosis 8,9 .…”
mentioning
confidence: 99%
“…We now believe that the primary cause of the congenital chylothorax was impairment of the systemic venous return, worsened by the obstructed and hypoplastic pulmonary venous system. Owing to reduced pulmonary blood flow in the fetus it is very difficult to visualize all four pulmonary veins 9 . Therefore, pulmonary venous hypoplasia is not amenable to prenatal diagnosis.…”
mentioning
confidence: 99%