Abstract: Respiratory rate is recognized as a clinically important parameter for monitoring respiratory status on the general care floor (GCF). Currently, intermittent manual assessment of respiratory rate is the standard of care on the GCF. This technique has several clinically-relevant shortcomings, including the following: (1) it is not a continuous measurement, (2) it is prone to observer error, and (3) it is inefficient for the clinical staff. We report here on an algorithm designed to meet clinical needs by provid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
40
1

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 68 publications
(46 citation statements)
references
References 45 publications
5
40
1
Order By: Relevance
“…The only significant age cohort omitted was the neonatal cohort. This is in keeping with recent work by Addison et al [2], who published a study of a RR algorithm for use with the PPG which was tested on data acquired from adult patients across the general care floor with a wide range of medical conditions and ages. This study is limited, however, by not including data from patients outside of the hospital setting, and by using data acquired from patients whilst being stationary, rather than truly ambulatory.…”
Section: Discussionsupporting
confidence: 77%
“…The only significant age cohort omitted was the neonatal cohort. This is in keeping with recent work by Addison et al [2], who published a study of a RR algorithm for use with the PPG which was tested on data acquired from adult patients across the general care floor with a wide range of medical conditions and ages. This study is limited, however, by not including data from patients outside of the hospital setting, and by using data acquired from patients whilst being stationary, rather than truly ambulatory.…”
Section: Discussionsupporting
confidence: 77%
“…22,23 The algorithm has been incorporated into a commercially available software application that reports respiratory rate continuously from a standard pulse oximeter. We characterized the performance of this software application in healthy subjects and patients hospitalized in a low-acuity care setting to obtain regulatory clearance.…”
mentioning
confidence: 99%
“…The probe provided continuous simultaneous monitoring of SpO 2 , heart rate, and RR for patients general care floor, including seven OSA patients (44). They found out that PPG-derived RR is comparable to the rate derived from EtCO 2 waveform as reference.…”
Section: Ppg-derived Signal For Rrmentioning
confidence: 99%