2013
DOI: 10.1080/08957959.2013.852190
|View full text |Cite
|
Sign up to set email alerts
|

Pulsed neutron powder diffraction at high pressure by a capacity-increased sapphire anvil cell

Abstract: A new design of opposed anvil cell for time-of-flight neutron powder diffraction was prepared for use at advanced pulsed sources. A couple of single-crystal sapphire sphere anvils and a gasket of fully hardened Ti-Zr null alloy were combined to compress 35 mm 3 of sample volume to 1 GPa and 11 mm 3 to 2 GPa of pressures, respectively. A very high-quality powder diffraction pattern was obtained at Japan Proton Accelerator Research Complex for a controversial high pressure phase of methane hydrate. The counting … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…Deuterium in the ringwoodite was analyzed using the Engineering Materials Diffractometer “TAKUMI” installed at Materials and Life Science Experimental Facility at Japan Proton Accelerator Research Complex (J‐PARC) [ Harjo et al ., ]. The powder was loosely placed into a cylindrical container composed of hardened Ti‐Zr null alloy with neutron transparency in which the outer and inner diameters were 3.0 mm and 2.4 mm, respectively [ Okuchi et al ., ]. Radial collimators of 5 mm gauge volume were applied to shield background neutrons from air or other scatterers.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Deuterium in the ringwoodite was analyzed using the Engineering Materials Diffractometer “TAKUMI” installed at Materials and Life Science Experimental Facility at Japan Proton Accelerator Research Complex (J‐PARC) [ Harjo et al ., ]. The powder was loosely placed into a cylindrical container composed of hardened Ti‐Zr null alloy with neutron transparency in which the outer and inner diameters were 3.0 mm and 2.4 mm, respectively [ Okuchi et al ., ]. Radial collimators of 5 mm gauge volume were applied to shield background neutrons from air or other scatterers.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…We used a newly designed high-pressure cell that was optimized for neutron-scattering measurements with strong pulsed-neutron sources [21,22]. In brief, two anvils composed of single-crystal moissanite and sintered polycrystalline diamond with 5 mm culets were used to compress a powdered Mg(OD)2 sample, which was confined within the f-TiZr gasket (initial thickness = 1 mm) and then compressed between the two anvils to 9 GPa.…”
Section: Application Of the F-tizr Alloymentioning