1997
DOI: 10.1109/28.633822
|View full text |Cite
|
Sign up to set email alerts
|

Pulsed-plasma treatment of polluted gas using wet-/low-temperature corona reactors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

1999
1999
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(12 citation statements)
references
References 5 publications
0
12
0
Order By: Relevance
“…The discharge power is computed by sampling the voltage and the corresponding current, there by obtaining the instantaneous power. Later the average power is obtained by averaging over the instantaneous values [25]. The power computed for the case of DC corona is found to be much lesser than that of the AC corona (~ 10 times).…”
Section: Corona Discharge Activitymentioning
confidence: 99%
“…The discharge power is computed by sampling the voltage and the corresponding current, there by obtaining the instantaneous power. Later the average power is obtained by averaging over the instantaneous values [25]. The power computed for the case of DC corona is found to be much lesser than that of the AC corona (~ 10 times).…”
Section: Corona Discharge Activitymentioning
confidence: 99%
“…After determining the maximum current, phase shift control is necessary for satisfying the minimum current of the load requirement and preventing drop-out. The phase shift angle for satisfying the minimum output current with phase shift control can be calculated using Equation (1). The consideration point for satisfying the phase shift angle which is calculated to regulate the minimum output current in the inverter is the phase difference between the inverter voltage and the current.…”
Section: Analysis Of Lcl Resonant Networkmentioning
confidence: 99%
“…The phase shift control is also necessary for satisfying the minimum output current of the LCCL network. In this case, the phase shift angle satisfying the minimum output current can be calculated using Equation (1), and the phase shift angle is equal to the case of the LCL network case because both networks are designed for the same maximum current. In the case of the LCL network, designing the phase difference between the inverter voltage and current is difficult because the values of Lr, Cr, and Llkg are already fixed in order to satisfy the maximum output current.…”
Section: Analysis Of Lccl Resonant Networkmentioning
confidence: 99%
See 2 more Smart Citations