1983
DOI: 10.1021/ac00254a031
|View full text |Cite
|
Sign up to set email alerts
|

Pulsed signal collection for laser-enhanced ionization spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
6
0

Year Published

1985
1985
1999
1999

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…Various methods have thus been explored to eliminate this effect. Among them are, for instance, increase of voltage applied to the electrodes, 11,14,15 employment of pulsed voltage-biased collectors, 12,16 modification of electrode configuration, 8,11,14,15 pretreatment with a chromatographic method, 17,18 and acidification of the sample solution. 19 Recently, we developed an alternative to reduce the electrical interference by interfacing a flow injection (FI) system to the LEI apparatus.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Various methods have thus been explored to eliminate this effect. Among them are, for instance, increase of voltage applied to the electrodes, 11,14,15 employment of pulsed voltage-biased collectors, 12,16 modification of electrode configuration, 8,11,14,15 pretreatment with a chromatographic method, 17,18 and acidification of the sample solution. 19 Recently, we developed an alternative to reduce the electrical interference by interfacing a flow injection (FI) system to the LEI apparatus.…”
mentioning
confidence: 99%
“…Various methods have thus been explored to eliminate this effect. Among them are, for instance, increase of voltage applied to the electrodes, ,, employment of pulsed voltage-biased collectors, , modification of electrode configuration, ,,, pretreatment with a chromatographic method, , and acidification of the sample solution …”
mentioning
confidence: 99%
“…ducibility in LEI detection. 54 In an effort to eliminate the electrical interference, we designed an apparatus by interfacing flow injection analysis (FIA) to the LEI device. In this way, the electrical interference was effectively reduced, and the linear dynamic range of sample concentration was much extended.…”
Section: A Technique To Diminlsh Electrical Interferencementioning
confidence: 99%
“…f ment, . improvement 0 e ectr e esign, mcrease 0 biased voltage,7.49.s2.~land employment of pulsed voltage-biased collectors 54. These current methods, although effective to diminish electrical interference, may somehow cause such side effects as disturbance of the flame structure.i" complication of the flame composition," or lack of repro-Indium concentration dependence in conventional LEI detection in a solution with varied Na concentration added as the matrix.…”
mentioning
confidence: 99%
“…More recently, several treatments of signal collection in LEI spectrometry have been useful additions to the general theory (3,4). Investigators have reported interferences with LEI spectrometry in a series of papers (5)(6)(7)(8)(9)(10) 0003-2700/85/0357-0016$01.50/0 © 1984 American Chemical Society that identify and suggest ways of minimizing these effects. The performance of cylindrical (rod) and flat (plate) electrodes has been characterized and evaluated in several studies (5,6).…”
mentioning
confidence: 99%