1997
DOI: 10.1063/1.1148116
|View full text |Cite
|
Sign up to set email alerts
|

Pulsed thrust measurements using laser interferometry

Abstract: An optical interferometric proximeter system (IPS) for measuring thrust and impulse bit of pulsed electric thrusters was developed. Unlike existing thrust stands, the IPS-based thrust stand offers the advantage of a single system that can yield electromagnetic interference-free, high accuracy (<2% error) thrust measurements within a very wide range of impulses (100 μN s to above 10 N s) covering the impulse range of all known pulsed plasma thrusters. In addition to pulsed thrusters, the IPS is theoretic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
33
0

Year Published

2002
2002
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 78 publications
(33 citation statements)
references
References 9 publications
0
33
0
Order By: Relevance
“…There are two thrust measurement systems typically used for the characterization of electric propulsion technologies: the torsion balance and pendulum thrust stand. The torsion balance is used routinely to determine the thrust produced by pulsed discharges [1][2][3] and has also been used for steady state systems. 4,5 Its mechanical structure allows a rapid response to an applied impulse and thrusts of the order of nano Newtons have been measured to ±2% error; 6 however, a damping system is required which adds to the system complexity.…”
Section: Introductionmentioning
confidence: 99%
“…There are two thrust measurement systems typically used for the characterization of electric propulsion technologies: the torsion balance and pendulum thrust stand. The torsion balance is used routinely to determine the thrust produced by pulsed discharges [1][2][3] and has also been used for steady state systems. 4,5 Its mechanical structure allows a rapid response to an applied impulse and thrusts of the order of nano Newtons have been measured to ±2% error; 6 however, a damping system is required which adds to the system complexity.…”
Section: Introductionmentioning
confidence: 99%
“…It is worth mentioning that, for the same discharge voltage, coil currents and propellant flows, values of the discharge current measured at the EPPDL vacuum facility 13 were generally about 10% lower than those measured at the PPPL Small Hall Thruster facility. This apparently was due to the fact that the operating background pressure of Xe (about 1×10 -5 Torr for the total propellant flow rate of 0.8 mg/s) was typically 5-7 times lower than that at the PPPL facility.…”
Section: Methodsmentioning
confidence: 99%
“…The EPPDL thrust stand 13 was designed to measure accurately impulse bits for pulsed plasma thrusters (PPTs) within the range of 10 -4 -10…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…[1][2][3] Generally, the impulse generated by a device is investigated by measuring the maximum deflection of the balance caused by a given impulse. [2,3] There are two major shortcomings of this approach.…”
Section: Introductionmentioning
confidence: 99%