PulseDIA: in-depth data independent acquisition mass spectrometry using enhanced gas phase fractionation

Abstract: An inherent bottleneck of data independent acquisition (DIA) analysis by Orbitrap-based mass spectrometers is the relatively large window width due to the relatively slow scanning rate compared to TOF. Here we present a novel gas phase separation and MS acquisition method called PulseDIA-MS, which improves the specificity and sensitivity of Orbitrap-based DIA analysis. This is achieved by dividing the ordinary DIA-MS analysis covering the entire mass range into multiple injections for DIA-MS analyses with comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 36 publications
0
11
0
Order By: Relevance
“…12 Two microliters of peptides (0.25 μg/μL) were separated at a flow rate of 300 nL/min along a 45 min 3−28% linear LC gradient (buffer A: 2% ACN, 0.1% FA in MS grade water; buffer B: 98% ACN, 0.1% FA in MS grade water) on a precolumn (3 μm, 100 Å, 20 mm × 75 μm, Thermo Fisher Scientific), followed by an analytical column (1.9 μm, 100 Å, 150 mm × 75 μm), using the Ultimate 3000 nanoLC-MS/MS system (Dionex LC-Packings) coupled with a QEHF-X (Thermo Fisher Scientific). 12 The PulseDIA was performed over a m/z ranging from 390 to 1210 at a resolution of 60 000 (at m/z 200) in an Orbitrap using an AGC target value of 3E6 charges and ion funnel RF settings of 40. The PulseDIA method was performed with four injections, and the fixed isolation window was used as described previously.…”
Section: Pulsedia-ms Acquisitionmentioning
confidence: 99%
See 2 more Smart Citations
“…12 Two microliters of peptides (0.25 μg/μL) were separated at a flow rate of 300 nL/min along a 45 min 3−28% linear LC gradient (buffer A: 2% ACN, 0.1% FA in MS grade water; buffer B: 98% ACN, 0.1% FA in MS grade water) on a precolumn (3 μm, 100 Å, 20 mm × 75 μm, Thermo Fisher Scientific), followed by an analytical column (1.9 μm, 100 Å, 150 mm × 75 μm), using the Ultimate 3000 nanoLC-MS/MS system (Dionex LC-Packings) coupled with a QEHF-X (Thermo Fisher Scientific). 12 The PulseDIA was performed over a m/z ranging from 390 to 1210 at a resolution of 60 000 (at m/z 200) in an Orbitrap using an AGC target value of 3E6 charges and ion funnel RF settings of 40. The PulseDIA method was performed with four injections, and the fixed isolation window was used as described previously.…”
Section: Pulsedia-ms Acquisitionmentioning
confidence: 99%
“…The PulseDIA method was performed with four injections, and the fixed isolation window was used as described previously. 12 The MS2 spectra were acquired at a resolution of 30 000 (at m/z 200) in the Orbitrap using an AGC target value of 1E6 and max IT of 50 ms.…”
Section: Pulsedia-ms Acquisitionmentioning
confidence: 99%
See 1 more Smart Citation
“…Various schemes of DIA strategies have been implemented since the beginning of this century, including but not limited to Shotgun CID, [9] DIA, [5] MS E , [10] PAcIFIC, [11] AIF, [12] SWATH-MS, [6] MSX, [13] SONAR, [14] WiSIM, [15] BoxCar DIA, [16] Scanning SWATH, [17] diaPASEF, [18] and PulseDIA [19] (Figure 1, Table 1), but not all schemes have been widely revisited. In Shotgun collision-induced dissociation (Shotgun CID) [9] induces in-source fragmentations where all ions co-eluting from chromatographic separation into the mass spectrometer are fragmented in parallel.…”
Section: Various Implementations Of Dia-based Proteomicsmentioning
confidence: 99%
“…The data acquisition method BoxCar [16] increasing the MS1 dynamic range is also available on DIA. PulseDIA [19] is an iterative gas phase fractionation method in which replicate sample injections are analyzed using differentially segmented DIA-MS methods in order to decrease window width and improve specificity and sensitivity, enabling nearly equal distribution of the proteome into any number of fractions. Recently parallel accumulation-serial fragmentation combined with data-independent acquisition (diaPASEF) was developed to utilize the ion mobility of peptide precursor in a trapped ion mobility mass spectrometer (TIMS) that can fully sample peptide precursor ion current Fangfei Zhang obtained her master's degree in Bioinformatics from ETH Zurich in March 2019 supervised by Prof. Dr. Ruedi Aebersold focusing on the histone posttranslational modifications using data-independent acquisition (DIA).…”
Section: Various Implementations Of Dia-based Proteomicsmentioning
confidence: 99%