2017
DOI: 10.1016/j.conbuildmat.2017.04.057
|View full text |Cite
|
Sign up to set email alerts
|

Punching shear strength of reinforced concrete slabs with plastic void formers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
15
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 35 publications
(16 citation statements)
references
References 16 publications
1
15
0
Order By: Relevance
“…In this paper, for different ratios of axial load acting on the beam to Euler buckling load, analytical solutions and frequency factors are evaluated. It is shown that the results obtained by VIM method in this paper are in compliance with the differential transform method (DTM) results for fixed-pinned case [10][11][12][13][14]. Also, homotopy perturbation method (HPM) was applied for free vibration of a beam on elastic foundation by Ozturk and Coskun [15].…”
Section: Introductionsupporting
confidence: 70%
See 1 more Smart Citation
“…In this paper, for different ratios of axial load acting on the beam to Euler buckling load, analytical solutions and frequency factors are evaluated. It is shown that the results obtained by VIM method in this paper are in compliance with the differential transform method (DTM) results for fixed-pinned case [10][11][12][13][14]. Also, homotopy perturbation method (HPM) was applied for free vibration of a beam on elastic foundation by Ozturk and Coskun [15].…”
Section: Introductionsupporting
confidence: 70%
“…Table 3 lists the mechanical features of the test slab bars. The bars located at the bottom and top substrates were 8 mm in width [12].…”
Section: Specimens and Materialsmentioning
confidence: 99%
“…In research context, some authors have limited this solid concrete area to a cross type configuration, by also using shear reinforcement in these concrete solid zones. 7 By testing lightweight type slabs with this concrete solid cross type configuration, as well as slabs with lightweight components in their total area, they verified that the first type of slabs has presented a punching capacity 18% higher than the one registered in the second type slab. 7 Held and Pfeffer 4 tested six BD slabs without solid concrete zones around the vertical supporting elements and without punching reinforcement.…”
Section: Introductionmentioning
confidence: 80%
“…7 By testing lightweight type slabs with this concrete solid cross type configuration, as well as slabs with lightweight components in their total area, they verified that the first type of slabs has presented a punching capacity 18% higher than the one registered in the second type slab. 7 Held and Pfeffer 4 tested six BD slabs without solid concrete zones around the vertical supporting elements and without punching reinforcement. This experimental program was composed by two series of three slab prototypes, one with slab's dimensions of 2,500 × 2,500 × 240 mm 3 , and the other of 2,500 × 2,500 × 450 mm 3 , made by concrete of average compressive strength of 30 and 40 MPa, respectively.…”
Section: Introductionmentioning
confidence: 80%
See 1 more Smart Citation