LCL-type grid-connected filter circuits are widely used for line network transmission because of their high ability to suppress current harmonics. However, due to the presence of resonance points in this third-order circuit, the system can generate severe oscillations. In order to improve power quality, a combined feed-forward factor control strategy is proposed in this paper. The control system introduces a combined feed-forward factor and incorporates the idea of dual PI control to ensure that the order of the system is reduced while improving its stability, followed by a detailed derivation of the constraint equations for each link parameter. The simulation verifies that the control scheme can regulate the output voltage of the line network and effectively reduce the harmonic content of the line network, providing a reference for reducing the harmonic content of grid-connected currents in engineering.