2020
DOI: 10.3390/s20236982
|View full text |Cite
|
Sign up to set email alerts
|

QCM Sensor Arrays, Electroanalytical Techniques and NIR Spectroscopy Coupled to Multivariate Analysis for Quality Assessment of Food Products, Raw Materials, Ingredients and Foodborne Pathogen Detection: Challenges and Breakthroughs

Abstract: Quality checks, assessments, and the assurance of food products, raw materials, and food ingredients is critically important to ensure the safeguard of foods of high quality for safety and public health. Nevertheless, quality checks, assessments, and the assurance of food products along distribution and supply chains is impacted by various challenges. For instance, the development of portable, sensitive, low-cost, and robust instrumentation that is capable of real-time, accurate, and sensitive analysis, qualit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 28 publications
(11 citation statements)
references
References 266 publications
(316 reference statements)
0
11
0
Order By: Relevance
“…In our developed system, we used an amplifier gain of 34, which gave a calculated system sensitivity of approximately 1.43 mV/Hz. The measurable frequency shift range was approximately from 0 Hz to 1400 Hz with that sensitivity, which was a suitable frequency range for detecting most VOCs of interest [5][6][7][8][9][10].…”
Section: Measurement Circuit Designmentioning
confidence: 94%
See 1 more Smart Citation
“…In our developed system, we used an amplifier gain of 34, which gave a calculated system sensitivity of approximately 1.43 mV/Hz. The measurable frequency shift range was approximately from 0 Hz to 1400 Hz with that sensitivity, which was a suitable frequency range for detecting most VOCs of interest [5][6][7][8][9][10].…”
Section: Measurement Circuit Designmentioning
confidence: 94%
“…Quartz crystal microbalance (QCM) has become one of the most common mass sensing techniques and has seen a wide variety of industrial applications, such as electronic noses [1,2] and electronic tongues [3,4]. These applications include food quality control [5][6][7][8], various forms of chemical detection [9,10], and biomolecular recognition [6][7][8]. Recently, QCM techniques with specialized sensor coatings have been widely applied for multiple analyte detections through the construction of multi-sensor arrays.…”
Section: Introductionmentioning
confidence: 99%
“…Barnaby et al correlated the grain chalk of rice to the genomic regions of NIR spectra [101]. These spectral regions can be applied in the automation of grain chalk quantification and potentially for other grain products as well [131].…”
Section: Nir Spectroscopy In Rice Authenticationmentioning
confidence: 99%
“…QCM is the most popular and widely used acoustic transducer for sensor applications that has become widely acceptable in chemical and biosensing fields. The practical importance of QCM has been well-emphasized in the literature, as this technology can be used in various areas, such as: environmental monitoring [ 41 ], food industries [ 42 ], viscosity measurement [ 43 ], humidity and gas sensors, metal film deposition, biosensing, etc. [ 44 ].…”
Section: Sensing Principles Of Qcmmentioning
confidence: 99%