2022
DOI: 10.1016/j.phymed.2022.154452
|View full text |Cite
|
Sign up to set email alerts
|

Qing-Chang-Hua-Shi granule ameliorates DSS-induced colitis by activating NLRP6 signaling and regulating Th17/Treg balance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 20 publications
(4 citation statements)
references
References 40 publications
0
4
0
Order By: Relevance
“…An imbalance in the ratio of Treg to Th17 cells in the gut is a common characteristic typical of colitis. Therefore, upregulating Treg cells in the gut to restore balance between Treg and Th17 cells has been identified as a viable strategy for managing colitis [ 12 15 ]. It has been reported that MSCs induce Treg cell differentiation, which in turn limits the inflammatory response [ 16 , 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…An imbalance in the ratio of Treg to Th17 cells in the gut is a common characteristic typical of colitis. Therefore, upregulating Treg cells in the gut to restore balance between Treg and Th17 cells has been identified as a viable strategy for managing colitis [ 12 15 ]. It has been reported that MSCs induce Treg cell differentiation, which in turn limits the inflammatory response [ 16 , 17 ].…”
Section: Introductionmentioning
confidence: 99%
“…Aliquots of QTF samples were thawed and prepared for UPLC-MS analysis as described in a previous publication. 24 A 5 μL aliquot of prepared QTF was filtered through a 0.22 µm filter and analyzed using a UPLC-ESI-Q-orbitrap-MS system, consisting of the Shimadzu Nexera X2 LC-30AD and the Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer by Thermo Scientific, San Jose, USA. ACQUITY UPLC ® high strength silica (HSS) T3 columns (2.1×100 mm, 1.8μm) from Waters, Milford, MA, USA, were employed for liquid chromatography separation with a flow rate of 0.3 mL/min.…”
Section: Methodsmentioning
confidence: 99%
“…The following parameters were applied: sheath gas flow rate, 45 psi; aux gas flow rate, 15 psi; capillary temperature, 400 °C; full ms resolution, 70,000; MS/MS resolution, 17,500; collision energy, 15/30/45 in NCE mode; and spray voltage, 4.0 kV (ESI+) or − 3.6 kV (ESI-). The mass spectrometry fragments of the tested sample XKY were matched with the in-house secondary mass spectrometry database (Shanghai BIOTREE Biotech Co., Ltd) [ 24 ].…”
Section: Methodsmentioning
confidence: 99%