2022
DOI: 10.3389/fdgth.2022.912353
|View full text |Cite
|
Sign up to set email alerts
|

Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life

Abstract: The photoplethysmographic (PPG) signal has been applied in various research fields, with promising results for its future clinical application. However, there are several sources of variability that, if not adequately controlled, can hamper its application in pervasive monitoring contexts. This study assessed and characterized the impact of several sources of variability, such as physical activity, age, sex, and health state on PPG signal quality and PPG waveform parameters (Rise Time, Pulse Amplitude, Pulse T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 62 publications
0
5
0
Order By: Relevance
“…As reported, the waveform clearly exhibits all the main fiducial points of a PPG signal, i.e., the systolic foot (representing the beginning of the systolic heart phase), the systolic peak (representing the maximum blood volume during the systolic phase), the dicrotic notch (corresponding to the closure of the aortic valve prevalently seen in the descending phase of young subjects with healthy compliant arteries [ 54 ]), and the diastolic peak (corresponding to both the diastolic heart phase and the peripheral wave reflection). Given that all the fiducial points are visible, the acquired signal can be considered as having a “diagnostic quality” according to Moscato et al [ 55 ], thus allowing a more in-depth morphological analysis if compared to “basic” quality signals.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As reported, the waveform clearly exhibits all the main fiducial points of a PPG signal, i.e., the systolic foot (representing the beginning of the systolic heart phase), the systolic peak (representing the maximum blood volume during the systolic phase), the dicrotic notch (corresponding to the closure of the aortic valve prevalently seen in the descending phase of young subjects with healthy compliant arteries [ 54 ]), and the diastolic peak (corresponding to both the diastolic heart phase and the peripheral wave reflection). Given that all the fiducial points are visible, the acquired signal can be considered as having a “diagnostic quality” according to Moscato et al [ 55 ], thus allowing a more in-depth morphological analysis if compared to “basic” quality signals.…”
Section: Resultsmentioning
confidence: 99%
“…The compact design of the device (in terms of its shape, size, and weight) minimizes the space occupied on the body, thus significantly reducing any discomfort experienced by the user. Moreover, the measurements carried out highlighted the high-quality of the acquired signals, with particular regard to the PPG waveform that exhibits all the main fiducial points used in literature, thus paving the way for the exploitation of our system for further morphological analyses [ 55 ].…”
Section: Discussionmentioning
confidence: 99%
“…When approaching the study of bio parameters, a number of factors must be taken into account. Cancer pain research and investigation on APA should prioritize examining the underlying pathophysiological mechanisms and evaluating the effectiveness of study models for different types of pain [ 97 ]. Cancer-induced neuropathic pain, for instance, has distinct pathophysiology, and this issue should be carefully addressed during the collection and analysis of physiological signals [ 98 ].…”
Section: Research Perspectives and Issuesmentioning
confidence: 99%
“…It saves computational resources by excluding low-quality pulses whilst retaining diagnostic quality pulses for analysis. During the daytime, only a small number of pulses can be expected to be of excellent quality and therefore suitable for PWA analysis (Moscato et al 2022). Many factors influence the morphology of pulse waves.…”
Section: Current and Future Challengesmentioning
confidence: 99%
“…Indeed, as detailed in section 6 , studies have reported that between 44% and 86% of PPG signals collected are not of sufficient quality for pulse rate monitoring. PPG signal quality has been found to be substantially influenced by physical activity and health status (Moscato et al 2022 ). Therefore, optimal handling of imperfect PPG signals is of ultimate importance to realize the full potential of this ubiquitously available technology.…”
Section: Ppg Signal Quality: Not a Black And White Mattermentioning
confidence: 99%