2005
DOI: 10.1016/j.ejcts.2005.08.020
|View full text |Cite
|
Sign up to set email alerts
|

Quality assessment of distal S2AS connector anastomosis by 13MHz epicardial ultrasound

Abstract: In the pig, external caliper measurements provided a reliable quantitative estimate of inner graft and coronary diameter for connector size matching. Epicardial 13 MHz ultrasound is a promising method to assess coronary anastomosis quality even when connector metal is present.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2006
2006
2008
2008

Publication Types

Select...
2
1

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…Intraoperative anastomosis quality assessment may aid in the introduction of novel automated distal anastomosis connectors developed to facilitate the suturing process in minimally invasive approaches [43][44][45]. In the off-pump CABG pig model, ECUS was successfully used for quality assessment of a coronary connector anastomosis [45].…”
Section: Coronary Connector Anastomosismentioning
confidence: 99%
See 1 more Smart Citation
“…Intraoperative anastomosis quality assessment may aid in the introduction of novel automated distal anastomosis connectors developed to facilitate the suturing process in minimally invasive approaches [43][44][45]. In the off-pump CABG pig model, ECUS was successfully used for quality assessment of a coronary connector anastomosis [45].…”
Section: Coronary Connector Anastomosismentioning
confidence: 99%
“…In the off-pump CABG pig model, ECUS was successfully used for quality assessment of a coronary connector anastomosis [45]. Connectors that contain a substantial amount of metal [43], however, may generate too many imaging artefacts to allow adequate assessment of anastomosis geometry.…”
Section: Coronary Connector Anastomosismentioning
confidence: 99%
“…Coronary connectors may advance TECAB as well by providing a means to facilitate anastomosis construction and omit the tedious suturing process (Falk et al, 2003). ECUS can be used for size matching and quality assessment of some of the connectors (Budde et al, 2005).…”
Section: Future Of Tecabmentioning
confidence: 99%
“…6 LITA blood flow was measured with a calibrated transit time flow probe (size 3S) connected to a flowmeter (T208; Transonic Systems Inc, Ithaca, NY) at a mean blood pressure of 80 mm Hg.…”
Section: Hand-sutured Anastomotic Proceduresmentioning
confidence: 99%