Quality Assurance of Segmental Strain Values Provided by Commercial 2-D Speckle Tracking Echocardiography Using in Silico Models: A Report from the EACVI-ASE Strain Standardization Task Force

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 33 publications
0
2
0
Order By: Relevance
“…The software package EchoPac (GE healthcare, MA, USA) was used to calculate LV volume and strain in the longitudinal, radial, and circumferential direction for each of the 17 segments of the LV defined by the American Heart Association (AHA). 8 , 32 LV pressures of the patients were measured invasively during CRT- implantation, while the pressure for the healthy subjects was set using reported values of healthy LVs synchronized to valve events for each control. Echocardiographic images were used to create 3D tetrahedral meshes of the LV, and rule-based fiber orientation was assigned using the histologically validated algorithm described in Ref.…”
Section: Methodsmentioning
confidence: 99%
“…The software package EchoPac (GE healthcare, MA, USA) was used to calculate LV volume and strain in the longitudinal, radial, and circumferential direction for each of the 17 segments of the LV defined by the American Heart Association (AHA). 8 , 32 LV pressures of the patients were measured invasively during CRT- implantation, while the pressure for the healthy subjects was set using reported values of healthy LVs synchronized to valve events for each control. Echocardiographic images were used to create 3D tetrahedral meshes of the LV, and rule-based fiber orientation was assigned using the histologically validated algorithm described in Ref.…”
Section: Methodsmentioning
confidence: 99%
“…A report from the European Association of Cardiovascular Imaging /American Society of Echocardiography strain standardization task force reported that the receiver operating characteristic curves to detect for segmental stretching of GE, Toshiba, and TomTec were 0.95, 0.97 and 0.84, respectively. 4) And finally, as with any software, the accuracy and reliability of strain measurements obtained using vendor-independent software can be influenced by the skill and experience of the user. As a result, clinicians or researchers using the software need to be properly trained and experienced in its use to obtain accurate and reliable results.…”
mentioning
confidence: 99%