2010
DOI: 10.1111/j.1365-2818.2009.03338.x
|View full text |Cite
|
Sign up to set email alerts
|

Quality control protocol for in vitro micro‐computed tomography

Abstract: SummaryThe aim of this work was to present and discuss a quality control protocol for in vitro micro-computed tomography (microCT), based on the adaptation of the quality control protocols for medical computed tomography. The importance of establishing a quality control protocol is related to the opportunity to identify problems on time comparing the microCT images acquired in different time points, and in this way to verify the performance of the device. The proposed quality control protocol was applied for a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 18 publications
0
11
0
Order By: Relevance
“…The data reported in this study were collected on speci c control charts and compared to baseline (BL) values, each de ned by upper and lower tolerance limits, as suggested by literature 25,31 . BL values were initially established for our Quantum GX micro-CT (PerkinElmer, Inc. Waltham, MA), acquiring ve consecutive scans of the QC phantoms 31,32 . For each monitored parameter, the BL and tolerance width were calculated, respectively:…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The data reported in this study were collected on speci c control charts and compared to baseline (BL) values, each de ned by upper and lower tolerance limits, as suggested by literature 25,31 . BL values were initially established for our Quantum GX micro-CT (PerkinElmer, Inc. Waltham, MA), acquiring ve consecutive scans of the QC phantoms 31,32 . For each monitored parameter, the BL and tolerance width were calculated, respectively:…”
Section: Methodsmentioning
confidence: 99%
“…Additionally, in-house-developed devices and protocols 15,30,31 are not easily applicable to other imaging centres.…”
Section: Introductionmentioning
confidence: 99%
“…Two quality assurance phantoms have been previously developed to directly measure the scaling accuracy of micro-CT images. 4,11,12 However, neither of these phantoms provided a traceable method to calibrate micro-CT image voxel sizes. In this paper, a quality assurance phantom qualified to a traceable standard is presented along with an automated image processing algorithm to characterize the scaling accuracy of micro-CT scanners.…”
Section: Introductionmentioning
confidence: 99%
“…These resolutions down to 100 nm are called nanoCT and may allow for imaging on the cellular level including the canal network, osteocyte lacunae, and even single cells. In addition, these machines can be used in the visualization of microfractures (Muller, 2009;Stock, 2009). A recent study used nanoCT to examine osteocyte lacunae and the canalicular network (Dierolf et al, 2010).…”
Section: Nanoctmentioning
confidence: 99%
“…When performing repeated microCT scanning, several factors must be optimized to minimize differences between scans. Repeated image acquisition requires special considerations including positioning, scanning medium (for ex vivo), image resolution, and uniform regions of interest (Stock, 2009). During processing, samples are filtered, segmented, registered, and uniform regions of interest are applied to create masks for differentiating between cortical and trabecular bone.…”
Section: Microct Scanningmentioning
confidence: 99%