2008
DOI: 10.1016/j.jelekin.2007.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of abdominal and pelvic floor muscle synergies in response to voluntary pelvic floor muscle contractions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
81
0
4

Year Published

2009
2009
2013
2013

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 87 publications
(87 citation statements)
references
References 37 publications
2
81
0
4
Order By: Relevance
“…The reliability of pressure data collected with this probe was previously tested by our group and was found to be excellent (r > 0.99). 18 The pressure transducer was interfaced directly with a 16-bit National Instruments analog-to-digital converter (NIDAQ PCI-MIO-16XE-10). The data were acquired at 1,000 Hz and stored on a personal computer using EMG Works 1 Acquisition software (Delsys 1 , www.delsys.com).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The reliability of pressure data collected with this probe was previously tested by our group and was found to be excellent (r > 0.99). 18 The pressure transducer was interfaced directly with a 16-bit National Instruments analog-to-digital converter (NIDAQ PCI-MIO-16XE-10). The data were acquired at 1,000 Hz and stored on a personal computer using EMG Works 1 Acquisition software (Delsys 1 , www.delsys.com).…”
Section: Methodsmentioning
confidence: 99%
“…In particular, Deindl et al 6 defined endurance as the time between the onset and the end of the EMG signal recorded from the PFMs using fine wire electrodes. As IVP during a PFM contraction is the product of both abdominal and PFM activity, 18 as well as passive stiffness, it is possible that the women in the different groups in the current study were using different motor control strategies to maintain IVP. Concurrent intra-abdominal pressure and EMG measures would be needed to determine whether there were differences in the muscle strategies used, for example, whether women with SUI rely more heavily on their abdominal muscles than their PFMs to sustain the IVP during a sustained vaginal squeeze task.…”
Section: Duration Of the Sustained Pfm Contractionmentioning
confidence: 99%
“…Może być przydatna na przykład, gdy uzyska się właściwą normalizację maksymalnej siły mięśniowej [49]. Ponadto EMG może być interesująca w aspekcie oceny aktywacji mięśni dna miednicy lub koaktywacji wraz z mięśniami otaczającymi [44,[50][51][52], a także w ocenie strefy odnerwienia [53,54].…”
Section: Elektromiografiaunclassified
“…A EMGs foi utilizada para mensurar a atividade elétrica dos MAP em diversas posturas corporais e durante a contração de grupos musculares específicos 6,8,15 .…”
Section: Sinergismo Dos Map Com Outros Grupos Muscularesunclassified
“…Em busca de avaliações mais precisas da função muscular do assoalho pélvico, novos métodos foram desenvolvidos e dentre eles destaca-se a eletromiografia de superfície (EMGs). Atualmente, observa-se o seu uso em diversos estudos sobre avaliação do assoalho pélvico, envolvendo mulheres com e sem disfunções dessa musculatura [4][5][6] . Alguns trabalhos que utilizaram a EMGs do assoalho pélvico constataram o sinergismo da musculatura abdominal, de membros superiores e antigravitacionais bem como o tempo de ativação do assoalho pélvico e dos músculos sinérgicos pode modificar-se de acordo com a situação do assoalho pélvico e a fase de vida da mulher 7,8 .…”
Section: Introductionunclassified