2020
DOI: 10.1101/2020.02.27.968636
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Quantification of Adeno-Associated Virus with Safe Nucleic Acid Dyes

Abstract: AbstractAdeno-associated virus (AAV) is the most commonly used viral vector for both biological and gene therapeutic applications1. Although many methods have been developed to measure quantity attributes of AAV, they are often technically challenging and time consuming. Here we report a method to titer AAV with GelGreen® dye, a safe green fluorescence nucleic acid dye recently engineered by Biotium company (Fremont, CA). This method, hereinafter referred t… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(8 citation statements)
references
References 46 publications
0
8
0
Order By: Relevance
“…Measurement of light scattering intensity at a single angle is sufficient for capsid detection in crude and purified samples. Measurement of light scatter at multiple angles is necessary for accurate determination of particle size and mass in highly purified samples [ 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 ].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Measurement of light scattering intensity at a single angle is sufficient for capsid detection in crude and purified samples. Measurement of light scatter at multiple angles is necessary for accurate determination of particle size and mass in highly purified samples [ 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 ].…”
Section: Discussionmentioning
confidence: 99%
“…The ability of intercalating dyes to pass through lipid membranes makes them natural candidates to evaluate titers of lipid enveloped viruses [ 42 , 43 , 44 , 45 ], but they are apparently not able to enter AAV capsids [ 47 ]. Figure 3 and Figure 4 confirm the inability of Picogreen to detect AAV-encapsidated DNA but reveal DNA associated with empty capsid exteriors.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…106 DyeBAs Direct quantification of the genome titer from at least crudely purified samples is possible using FS signals from dye-based binding assays (DyeBAs). The approach is simple and fast, requiring neither special instrumentation nor genome-dependent probes to yield results within 30 min-3 h. 59,60 The method is precise, with repeatability and intermediate precision reported within 4%-17% CV and 7%-16% CV, respectively. 59,60 Similar to PCR-based methods, DyeBA requires the removal of non-encapsidated DNA and capsid lysis during sample preparation.…”
Section: Cdmsmentioning
confidence: 98%