Quantification of Ceftaroline in Human Plasma Using High-Performance Liquid Chromatography with Ultraviolet Detection: Application to Pharmacokinetic Studies

Abstract: This study was conducted to develop a rapid, simple and reproducible method for the quantification of ceftaroline in plasma samples by high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Sample processing consisted of methanol precipitation and then, after centrifugation, the supernatant was injected into the HPLC system, working in isocratic mode. Ceftaroline was detected at 238 nm at a short acquisition time (less than 5 min). The calibration curve was linear over the concentration r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 25 publications
0
2
0
1
Order By: Relevance
“…The HPLC system was controlled with the Waters Breeze HPLC software (version 6.20.00.00.; Waters, Milford, MA, USA). The quantification of ceftaroline was performed according to a previously validated method [19], and for avibactam we developed and validated a new method. Table 2 features the conditions for quantification.…”
Section: Methodsmentioning
confidence: 99%
“…The HPLC system was controlled with the Waters Breeze HPLC software (version 6.20.00.00.; Waters, Milford, MA, USA). The quantification of ceftaroline was performed according to a previously validated method [19], and for avibactam we developed and validated a new method. Table 2 features the conditions for quantification.…”
Section: Methodsmentioning
confidence: 99%
“…Liquid chromatography methods coupled with mass–mass spectrometry (LC-MS/MS) or with UV detection (HPLC-UV) have been validated for the TDM of ceftaroline [ 35 , 36 ]. The clinical PK/PD targets for cephalosporin efficacy are set at 45–100%fT > MIC, based on the severity of the infection (MRSA vs. MSSA) and on the patients’ conditions (more aggressive targets should be considered in ICU settings) [ 37 ].…”
Section: β-Lactams: Fifth Generation Cephalosporinsmentioning
confidence: 99%
“…El límite de cuantificación fue 0,5 mg/L. La curva de calibración fue linear en el rango de concentraciones de 0,5 a 100 mg/L, y la precisión y exactitud fueron ≤ 15% a altas, medias y bajas concentraciones y [ 3 ]…”
unclassified