Quantification of elemental mapping of heterogeneous geological sample by laser ablation inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 41 publications
0
3
0
1
Order By: Relevance
“…The integration times for the following isotopes were 12 C (0.01 s), 28 Si (0.1 s), 63 Cu (0.1 s), 66 Zn (0.1 s), and 195 Pt (0.3 s). The operating conditions, namely, laser beam fluence (8 J cm –2 ), laser repetition rate (10 Hz), scan speed (200 μm s –1 ), laser spot diameter (100 μm), and spacing (100 μm), were optimized according to Vaculovic et al 2015, and the influence of different ablation rates in various zones, according to Anyz et al 2017. , The measurement of the sample takes a maximum of 2 h.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The integration times for the following isotopes were 12 C (0.01 s), 28 Si (0.1 s), 63 Cu (0.1 s), 66 Zn (0.1 s), and 195 Pt (0.3 s). The operating conditions, namely, laser beam fluence (8 J cm –2 ), laser repetition rate (10 Hz), scan speed (200 μm s –1 ), laser spot diameter (100 μm), and spacing (100 μm), were optimized according to Vaculovic et al 2015, and the influence of different ablation rates in various zones, according to Anyz et al 2017. , The measurement of the sample takes a maximum of 2 h.…”
Section: Methodsmentioning
confidence: 99%
“…We understand that not everyone has access to tumor samples, but this method can also be used to display other types of more available samples (i.e., granite 27 or leaves 28 ).…”
Section: Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…Analýza byla prováděna u každého vzorku na 5 místech a složení vzorku je vyjádřeno jako průměrná hodnota. Kvantifikace výsledků byla provedena s využitím certifikovaného referenčního skleněného materiálu NIST 610 a normalizací na sumu oxidů pro potlačení vlivu různé ablační rychlosti (Halicz -Gunther 2004;Vaculovič et al 2017). Správnost výsledků byla ověřena analýzou certifikovaných referenčních skleněných materiálů NIST612 a Corning.…”
Section: Laserová Ablace S Hmotnostní Spektrometrií Indukčně Vázaného Plazmatu (La-icp-ms)unclassified