2012
DOI: 10.1016/j.foodchem.2012.05.100
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of furanic compounds in coated deep-fried products simulating normal preparation and consumption: Optimisation of HS-SPME analytical conditions by response surface methodology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(11 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…The HS‐SPME method used by Pérez‐Palacios et al . () with modifications was used for evaluation of volatile compounds in cooked ham samples. To extract volatile compounds, a PDMS‐DVB SPME fiber (65 μm thickness, Supelco Co., Bellefonte, PA) was used.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The HS‐SPME method used by Pérez‐Palacios et al . () with modifications was used for evaluation of volatile compounds in cooked ham samples. To extract volatile compounds, a PDMS‐DVB SPME fiber (65 μm thickness, Supelco Co., Bellefonte, PA) was used.…”
Section: Methodsmentioning
confidence: 99%
“…Volatile compounds were extracted by headspace solid phase microextraction (HS-SPME) and analyzed by chromatographic analysis (Varian 4000 GC-MS) coupled to a mass selective detector (Varian 240MS/4000 Mass Spec). The HS-SPME method used by Pérez-Palacios et al (2012) with modifications was used for evaluation of volatile compounds in cooked ham samples. To extract volatile compounds, a PDMS-DVB SPME fiber (65 μm thickness, Supelco Co., Bellefonte, PA) was used.…”
Section: Chemical Analyses Of Cooked Hammentioning
confidence: 99%
“…Analysis of furfuryl alcohol can be done by either gas and liquid chromatography with UV, biosensor, or fluorescence detection [ 5 , 6 , 14 , 15 , 16 , 17 ], while β-myrcene is typically determined using gas chromatography with mass spectrometry or flame ionization detection [ 18 , 19 , 20 , 21 ].…”
Section: Introductionmentioning
confidence: 99%
“…According to Pérez-Palacios et al (2012), an increase in extraction temperature leads to the release of a greater quantity of volatile compounds into the headspace, since the rise in temperature is proportional to the increase in the analyte diffusion coefficient. However, high temperatures can also lead to the formation of aromatic compounds derived from the Maillard reaction or from caramelization.…”
Section: Optimization Of Spme Parameters For Volatiles In Caprine Coamentioning
confidence: 99%