2013
DOI: 10.5301/ijao.5000236
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of Hemodialysis Dose: What Kt/V to Choose?

Abstract: The Kt/V index is different depending on the method used for its evaluation. The three methods can be used for quantification of hemodialysis with a better agreement between Kt/VDau and Kt/VBCM. In this study, Kt/VOCM results underestimate hemodialysis efficiency. This difference has to 
be considered when applying quantification of hemodialysis to clinical practice.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 41 publications
0
12
0
1
Order By: Relevance
“…This method does not require blood sampling and can be used with each dialysis treatment. However, more recent studies has shown that Kt/V OCM with V determined by Watson formula, leads to systematic underestimation of Kt/V by 22%–24% when comparing to Kt/V derived from urea reduction using the Daugirdas second generation equation …”
Section: Clinical Standard and Targetsmentioning
confidence: 96%
“…This method does not require blood sampling and can be used with each dialysis treatment. However, more recent studies has shown that Kt/V OCM with V determined by Watson formula, leads to systematic underestimation of Kt/V by 22%–24% when comparing to Kt/V derived from urea reduction using the Daugirdas second generation equation …”
Section: Clinical Standard and Targetsmentioning
confidence: 96%
“…It is now clearly recognized that anthropometric formulae overestimate total body water (V) in hemodialyzed patients by about 20% 22‐24 . This explains why the K ID t/V value calculated from ionic dialysance and Watson's formula underestimates sp Kt/V by about 20% and is close to e Kt/V 25 …”
Section: Ionic Dialysance Monitoringmentioning
confidence: 99%
“…The most validated and universally used parameter to evaluate the dialysis dose is the assessment of the urea removal rate by means of the Kt/V. In this parameter, "K" is the effective urea clearance (commonly accepted as the solute marker of uremic toxicity), «t» is the time of duration of the dialysis session and «V» is the urea volume of distribution [5]. The Kt/V is a crucial determinant in the clinical outcome of the patients on chronic HD, considering as an adequate Kt/V value ≥ 1.2 per session [6,7].…”
Section: Introductionmentioning
confidence: 99%