2011
DOI: 10.1016/j.chroma.2011.07.053
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of human growth hormone by amino acid composition analysis using isotope dilution liquid-chromatography tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 34 publications
(14 citation statements)
references
References 36 publications
0
14
0
Order By: Relevance
“…Protein purity was examined by RP-HPLC using a Kinetex C18 column (2.6 µm, 150×2.10 mm; Phenomenex, Torrance, CA, USA) [16]. Analytes were eluted using a linear gradient from 28% in buffer A (0.1% trifluoroacetic acid in H 2 O) to 100% in buffer B (0.1% trifluoroacetic acid in acetonitrile) at 40°C.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Protein purity was examined by RP-HPLC using a Kinetex C18 column (2.6 µm, 150×2.10 mm; Phenomenex, Torrance, CA, USA) [16]. Analytes were eluted using a linear gradient from 28% in buffer A (0.1% trifluoroacetic acid in H 2 O) to 100% in buffer B (0.1% trifluoroacetic acid in acetonitrile) at 40°C.…”
Section: Methodsmentioning
confidence: 99%
“…MALDI-TOF mass spectrometry was performed on an Autoflex III Smartbeam device (Bruker Daltonics, Billerica, MA, USA) [16]. Sample was mixed with the same volume of MALDI matrix (10 mg/mL of α-cyano-4-hydroxycinnamic acid) and spotted on a MALDI target plate.…”
Section: Methodsmentioning
confidence: 99%
“…This was included in the present study because a solution sample with the concentration determined through an amino acid analysis was available as a certified reference material. This protein, with a molecular mass of 22 124 Da, consists of 191 amino acid residues .…”
Section: Resultsmentioning
confidence: 99%
“…For the accurate and precise quantification of AAs, isotope‐labeled AAs were used as internal standards. The isotope dilution (ID) method is the most effective way to reduce uncertainties throughout the whole experimental procedure since the isotopic analogues exhibit the same chemical properties as those of unlabeled compounds, except for molecular mass . As six isotope‐labeled AAs (Ala*, Pro*, Val*, Ile*, Phe*, and Tyr*) were spiked into AA solutions for measurement, the RSDs of intra‐ and inter‐day assays were 0.8–2.8% and 0.6–2.7%, respectively (Table ).…”
Section: Resultsmentioning
confidence: 99%