2019
DOI: 10.1186/s12968-019-0567-y
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of lung water in heart failure using cardiovascular magnetic resonance imaging

Abstract: Background Pulmonary edema is a cardinal feature of heart failure but no quantitative tests are available in clinical practice. The goals of this study were to develop a simple cardiovascular magnetic resonance (CMR) approach for lung water quantification, to correlate CMR derived lung water with intra-cardiac pressures and to determine its prognostic significance. Methods Lung water density (LWD, %) was measured using a widely avail… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
52
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 24 publications
(57 citation statements)
references
References 33 publications
(35 reference statements)
4
52
1
Order By: Relevance
“…The FLORET (Fermat looped, orthogonally encoded trajectories) 3D spiral UTE sequence offers improved efficiency as compared with radial trajectories for lung imaging, 19 but was not developed specifically for or validated for LWD estimation. Alternatively, spin‐echo approaches address the T2 signal loss in the lungs and can be used to estimate water density, 3 but with unwanted T 2 weighting and potential sensitivity to motion and flow artifacts as well as incomplete spatial coverage of the lungs.…”
Section: Introductionmentioning
confidence: 99%
“…The FLORET (Fermat looped, orthogonally encoded trajectories) 3D spiral UTE sequence offers improved efficiency as compared with radial trajectories for lung imaging, 19 but was not developed specifically for or validated for LWD estimation. Alternatively, spin‐echo approaches address the T2 signal loss in the lungs and can be used to estimate water density, 3 but with unwanted T 2 weighting and potential sensitivity to motion and flow artifacts as well as incomplete spatial coverage of the lungs.…”
Section: Introductionmentioning
confidence: 99%
“…The amount of late gadolinium enhancement outperforms current guideline-recommended criteria in the identification of patients with hypertrophic cardiomyopathy at risk of sudden cardiac death [9] Thompson et al Quantification of lung water in heart failure using cardiovascular magnetic resonance imaging [10] Dabir et al Multiparametric cardiovascular magnetic resonance imaging in acute myocarditis: a comparison of different measurement approaches [11] Holtackers et al Clinical value of dark-blood late gadolinium enhancement cardiovascular magnetic resonance without additional magnetization preparation [12] Shusterman et al High-energy external defibrillation and transcutaneous pacing during MRI: feasibility and safety [18] Thompson et al * Quantification of lung water in heart failure using cardiovascular magnetic resonance imaging [10] Walheim et al Multipoint 5D flow cardiovascular magnetic resonance-accelerated cardiac-and respiratory-motion resolved mapping of mean and turbulent velocities [19] website. Over 95% found value in the open-access format with 23% using JCMR as a source for CME and over 75% finding benefit of using the SCMR membership benefit for an 80% discount in the article publication fee (APC).…”
Section: Survey Results For Jcmrmentioning
confidence: 99%
“…The associate editors and I select the Pohost finalists (Table 4 ) and the entire editorial board votes on the top prize. At the 2020 SCMR annual meeting in Orlando, Florida, the 13 th Gerald M. Pohost Prize was awarded to Dr. Thompson for their manuscript” Quantification of lung water in heart failure using cardiovascular magnetic resonance imaging.” [ 10 ]. The Pohost Runner-up Prize was awarded to Dr. Nickander for “The relative contributions of myocardial perfusion, blood volume and extracellular volume to native T1 and native T2 at rest and during adenosine stress in normal physiology.…”
Section: Pohost and Pennell Awardsmentioning
confidence: 99%
See 2 more Smart Citations