2018
DOI: 10.1016/j.jchromb.2018.07.009
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of ondansetron, granisetron and tropisetron in goat plasma using hydrophilic interaction liquid chromatography-solid phase extraction coupled with hydrophilic interaction liquid chromatography-triple quadrupole tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 59 publications
0
2
0
Order By: Relevance
“…According to the literature [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24], acetonitrile and acidic water media were selected to optimize the mobile phase composition. A series of concentrations, pH values, the ratio of aqueous potassium dihydrogen phosphate solution, and different chromatographic column types were studied to ensure good resolution and appropriate retention time of the five 5-HT 3 receptor antagonists.…”
Section: Optimization Of Chromatographic Conditionsmentioning
confidence: 99%
See 1 more Smart Citation
“…According to the literature [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24], acetonitrile and acidic water media were selected to optimize the mobile phase composition. A series of concentrations, pH values, the ratio of aqueous potassium dihydrogen phosphate solution, and different chromatographic column types were studied to ensure good resolution and appropriate retention time of the five 5-HT 3 receptor antagonists.…”
Section: Optimization Of Chromatographic Conditionsmentioning
confidence: 99%
“…HPLC is commonly used to verify rapid detection systems due to its attractive features, such as high peak efficiencies, great resolution, high sensitivity, good repeatability, and wide application range. HPLC analytic methods for the detection of 5-HT 3 receptor antagonists such as ODT, GNT, TPT, AZT, and RMT are already mature, and most of them use retention data in the qualitative analysis, while the external standard method (ESM) is applicable in quantitative analysis [7][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22][23][24]. However, some of these methods may take a long time, and the specific drugs to be tested must correspond to reference substances, which cannot meet the requirements of rapid drug detection.…”
Section: Introductionmentioning
confidence: 99%