2010
DOI: 10.1016/j.gaitpost.2009.09.004
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of soft tissue artifact in lower limb human motion analysis: A systematic review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

7
178
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 276 publications
(185 citation statements)
references
References 49 publications
7
178
0
Order By: Relevance
“…An intra-and inter-variability also appeared across the three subjects performing the running task although some similar patterns of force was observed. As STA is well known to be subject-and task-specific (Leardini et al, 2005;Peters et al, 2010), it was expected to obtain such differences.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…An intra-and inter-variability also appeared across the three subjects performing the running task although some similar patterns of force was observed. As STA is well known to be subject-and task-specific (Leardini et al, 2005;Peters et al, 2010), it was expected to obtain such differences.…”
Section: Discussionmentioning
confidence: 99%
“…It has been described, from a kinematics point of view, as the soft tissue artefact (STA). Indeed, this relative movement has a deleterious effect on the joint kinematics estimated from skin markers and motion capture systems (Leardini et al, 2005;Peters et al, 2010). At the same time, from a dynamics point of view, the soft tissue motion, modelled as wobbling masses connected to the rigid-body model of the lower limb, is also recognised to have an effect on the joint kinetics (i.e.…”
mentioning
confidence: 99%
“…STA is caused by a combination of skin stretching and sliding, muscle contractions, gravity and inertial effects (Leardini et al, 2005;Peters et al, 2010). Commonly used bone pose estimators (BPEs) define an appropriate marker cluster model and match the model with the measured marker trajectories at each time step by solving a least squares (LS) minimization problem constraining the cluster transformation to a translation and a rotation, with or without uniform scaling (Cappello et al, 1996;Challis, 1995;Söderkvist and Wedin, 1993;Spoor and Veldpaus, 1980).…”
Section: Introductionmentioning
confidence: 99%
“…When non-invasive techniques such as stereophotogrammetry are used, the accurate estimation of the position and orientation (pose) of a rigid bony segment from the measured position of markers attached to the skin is limited mostly by the relative motion between the markers and the bone, which is known as the Soft Tissue Artifact (STA) 26 . In the literature, several methods have been proposed that employ clusters composed of a redundant number of skin markers (>3) and which exploit this redundancy to minimize the effect of the STA on the estimation of the underlying bone pose, but no satisfactory solution yet exists 26,29 .…”
Section: Introductionmentioning
confidence: 99%