Quantification of the geometric uncertainty when using implanted markers as a surrogate for lung tumor motion

Abstract: Background Fiducial markers are used as surrogates for tumor location during radiation therapy treatment. Developments in lung fiducial marker and implantation technology have provided a means to insert markers endobronchially for tracking of lung tumors. This study quantifies the surrogacy uncertainty (SU) when using endobronchially implanted markers as a surrogate for lung tumor position. Methods We evaluated SU for 17 patients treated in a prospective electromagnetic‐guided MLC tracking trial. Tumor and mar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…MLTT using anatomical imaging, such as kV‐ or MV‐projections, is in principle superior to marker‐based lung target tracking because MLTT locates the target directly without the marker to tumor surrogacy uncertainties associated with inferring the target position from marker positions. A recent study estimated the surrogacy uncertainty of marker‐based lung target tracking approaches over a population of 17 lung SABR patients and found a mean surrogacy uncertainty of 5%–33% of the motion magnitude (95th percentile range of up to 2.3 mm) depending on the motion direction 27 . Therefore, MLTT approaches have the potential to achieve more accurate target localization than a marker‐based tracking approach.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…MLTT using anatomical imaging, such as kV‐ or MV‐projections, is in principle superior to marker‐based lung target tracking because MLTT locates the target directly without the marker to tumor surrogacy uncertainties associated with inferring the target position from marker positions. A recent study estimated the surrogacy uncertainty of marker‐based lung target tracking approaches over a population of 17 lung SABR patients and found a mean surrogacy uncertainty of 5%–33% of the motion magnitude (95th percentile range of up to 2.3 mm) depending on the motion direction 27 . Therefore, MLTT approaches have the potential to achieve more accurate target localization than a marker‐based tracking approach.…”
Section: Discussionmentioning
confidence: 99%
“…A recent study estimated the surrogacy uncertainty of marker-based lung target tracking approaches over a population of 17 lung SABR patients and found a mean surrogacy uncertainty of 5%-33% of the motion magnitude (95th percentile range of up to 2.3 mm) depending on the motion direction. 27 Therefore, MLTT approaches have the potential to achieve more accurate target localization than a marker-based tracking approach.…”
Section: F I G U R Ementioning
confidence: 99%
See 2 more Smart Citations
“…Clinical tumour tracking methods on standard treatment systems exists,9 18 19 however, they rely on the invasive implantation of fiducial markers around the tumour. The use of markers for lung cancer radiotherapy is costly in terms of toxicity and pain during marker placement,20 mistargeting due to migration and motion between the target and the markers,21 22 and the time and cost of the additional marker placement procedure.…”
Section: Introductionmentioning