Quantified versus willful handgrip exercises for the prevention of PICC-related thrombosis: A meta-analysis and systematic review

Abstract: Background: Thrombosis is a common yet serious complication in patients with peripherally inserted central venous catheter (PICC), the prevention of thrombosis is very important to the prognosis of PICC patients. We aimed to evaluate the effects of quantified versus willful grip exercises for the prevention of PICC-related thrombosis, to provide evidence to the clinical nursing care of PICC patients.Methods: Two authors searched PubMed et al databases for randomized controlled trials (RCTs) comparing the effec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…The probable causes for CRT included endothelial damage during vein puncture, hemodynamic change in vessels, site of CVC placement, size of CVC, flow speed in CVC, medicine used through CVC, and so on. [26][27][28][29][30][31] There were no differences in these parameters between groups. Different from the previous studies using systemic heparin infusion at a speed of 0.5 to 10 units/kg/h, 2,5,8 we continuously evenly infused heparin through each CVC at a speed of 2 to 3 units/kg/h in the non-CRT subgroup and 10 to 15 units/kg/h in the CRT subgroup.…”
Section: Discussionmentioning
confidence: 79%
See 1 more Smart Citation
“…The probable causes for CRT included endothelial damage during vein puncture, hemodynamic change in vessels, site of CVC placement, size of CVC, flow speed in CVC, medicine used through CVC, and so on. [26][27][28][29][30][31] There were no differences in these parameters between groups. Different from the previous studies using systemic heparin infusion at a speed of 0.5 to 10 units/kg/h, 2,5,8 we continuously evenly infused heparin through each CVC at a speed of 2 to 3 units/kg/h in the non-CRT subgroup and 10 to 15 units/kg/h in the CRT subgroup.…”
Section: Discussionmentioning
confidence: 79%
“…The probable causes for CRT included endothelial damage during vein puncture, hemodynamic change in vessels, site of CVC placement, size of CVC, flow speed in CVC, medicine used through CVC, and so on 26–31 . There were no differences in these parameters between groups.…”
Section: Discussionmentioning
confidence: 92%