2021
DOI: 10.1107/s2052252521008290
|View full text |Cite
|
Sign up to set email alerts
|

Quantifying magnetic anisotropy using X-ray and neutron diffraction

Abstract: In this work, the magnetic anisotropy in two iso-structural distorted tetrahedral Co(II) complexes, CoX 2tmtu2 [X = Cl(1) and Br(2), tmtu = tetramethylthiourea] is investigated, using a combination of polarized neutron diffraction (PND), very low-temperature high-resolution synchrotron X-ray diffraction and CASSCF/NEVPT2 ab initio calculations. Here, it was found consistently among all methods that the compounds have an easy axis of magnetization pointing nearly along the bisector of the comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 66 publications
1
6
0
Order By: Relevance
“…From this, a similar susceptibility ellipsoid was found, Figure (bottom), as well as a similar g z direction, Figure (10.1° offset to PNPD easy axis). The found discrepancies between easy axis directions from ab initio calculations and PND/PNPD measurements are of similar magnitudes to those found by other studies. , …”
Section: Resultssupporting
confidence: 88%
See 4 more Smart Citations
“…From this, a similar susceptibility ellipsoid was found, Figure (bottom), as well as a similar g z direction, Figure (10.1° offset to PNPD easy axis). The found discrepancies between easy axis directions from ab initio calculations and PND/PNPD measurements are of similar magnitudes to those found by other studies. , …”
Section: Resultssupporting
confidence: 88%
“…In contrast, the local magnetic anisotropy in paramagnetic compounds can be quantified using PND via the site susceptibility model . The method has been successfully used to determine the atomic susceptibility tensors in several SMMs. ,,,, Recently, the applicability of the method was extended to powder samples (polarized neutron powder diffraction, PNPD), alleviating the demanding need for large single-crystals and time-consuming measurements at multiple crystal orientations. However, this remarkable progress has so far only been exploited on a single occasion to study the atomic susceptibility tensor, without independent verification from the single-crystal method.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations