2022
DOI: 10.1016/j.jmsacl.2022.05.002
|View full text |Cite
|
Sign up to set email alerts
|

Quantitation of non-derivatized free amino acids for detecting inborn errors of metabolism by incorporating mixed-mode chromatography with tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 24 publications
0
11
0
Order By: Relevance
“…Our dual-column U(H)PLC-MRM-MS method provided lower LLOD and LLOQ concentrations for all amino acids analyzed and was 15 times faster than the gold standard (run time: 119 min) with total a run time of 7.9 min. Choi et al 32 , Liu et al 47 and DeArmond et al 33 recently developed HPLC-MRM- MS methods based on mixed-mode chromatography using hydrophilic interaction chromatography (HILIC) and cation exchange (CEX) properties to separate and quantify free amino acids. They achieved LLOQ values in the low µmolar range with analysis times ranging from 13 min 47 to 15 min 33 and 22 min 32 , respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Our dual-column U(H)PLC-MRM-MS method provided lower LLOD and LLOQ concentrations for all amino acids analyzed and was 15 times faster than the gold standard (run time: 119 min) with total a run time of 7.9 min. Choi et al 32 , Liu et al 47 and DeArmond et al 33 recently developed HPLC-MRM- MS methods based on mixed-mode chromatography using hydrophilic interaction chromatography (HILIC) and cation exchange (CEX) properties to separate and quantify free amino acids. They achieved LLOQ values in the low µmolar range with analysis times ranging from 13 min 47 to 15 min 33 and 22 min 32 , respectively.…”
Section: Resultsmentioning
confidence: 99%
“…The labeled AA are then separated using RPLC, IEX, or HILIC methods. The direct AA analysis is a simpler alternative to methods based on derivatization (DeArmond & Bunch, 2022). A simple and fast method combining pre‐column derivatization with RPLC‐MS analysis for AA quantification in protein and biopharmaceutical samples has been proposed.…”
Section: Ms‐based Methods In the Analysis Of Biopharmaceuticalsmentioning
confidence: 99%
“…The Intrada AAs column was specially designed for AAs analysis, allowing the separation of Leu and Ile without the need for derivatization. DeArmond et al [148] F I G U R E 5 1. Leucine isomers in plasma.…”
Section: Mixed-mode Chromatographymentioning
confidence: 99%
“…It is a simple analytical method that requires a short analysis time, and the separation of the isomers is significantly better than previously reported [145,146] (see Figure 5). DeArmond's study [148] showed that ACN and water are more conducive to the separation and ionization of Leu and Ile than MeOH and that the retention time is reduced. The results were compared with an AAs analyzer (Hitachi L-8800).…”
Section: Mixed-mode Chromatographymentioning
confidence: 99%
See 1 more Smart Citation